21-23-24.
indicates the selected test to measure the starting capacity of the
vehicle battery.
21-23-25.
indicates the selected test to measure the charge e ciency of the
vehicle alternator.
4. INSTALLATION
POSITIONING THE STARTER
When using the starter, position it on a horizontal, at and stable
surface.
OPERATING MODE
The starter comes on when you enter test mode, and the display
lights up when any button is pressed or when the output clamps
are connected to the vehicle battery terminals; the display light
automatically switches o when the clamps are disconnected from the
vehicle battery, and also when no button activity is acknowledged for
over 3 minutes. The starter switches o completely when: the clamps
are disconnected, no button activity is acknowledged for over 3
minutes and there is no absorption from the USB ports, jack sockets
and inputs.
4.1 Operating in TEST mode
Measure the vehicle battery charge status, its potential when
started and the charge e ciency of the alternator. To perform the
measurements, connect the clamps to the battery terminals with the
correct polarity.
Select the measurement to be performed by pressing the
button repeatedly.
4.1.1 VEHICLE BATTERY TEST
Measure the voltage at the battery terminals and calculate the charge
status.
Procedure
- Press button
repeatedly to select the WET GEL AGM PbCa Li
construction technology and the battery test function
- Connect the red clamp POS. (+) to the battery terminal POS. (+), then
connect the black clamp NEG. (-) to the vehicle chassis or the vehicle
battery terminal NEG. (-) if not previously connected.
- Use button
to select the battery voltage
model only).
The measured voltage is indicated on the display
battery status is indicated in graph format
4.1.2 VEHICLE ALTERNATOR CHARGE EFFICIENCY TEST
Measures the vehicle alternator charge e ciency.
Procedure
The vehicle engine does not need to be switched o to perform the
test correctly.
- Press button
repeatedly to select the (alternator) charge test
function
.
- Connect the red clamp POS. (+) to the battery terminal POS. (+), then
connect the black clamp NEG. (-) to the vehicle chassis or the vehicle
battery terminal NEG. (-) if not previously connected.
- Press button
to select the battery voltage
model only); the measurement data acquisition process is indicated
by the symbol
.
If the vehicle engine is switched o , the message "Bad" appears on the
display
.
- Switch on the engine if not running, taking it to approx. 1500 rpm;
- Switch on all the lights (full headlights, courtesy lights, etc.) and all
- Check the display
4.1.3 VEHICLE BATTERY STARTING CHARGE CAPACITY (CCA)
Measures the starting capacity of the vehicle battery.
Procedure
- Press button
- Make sure that the vehicle or boat to be started is switched o
- Connect the red clamp POS. (+) to the battery terminal POS. (+), then
- Press button
- The message "Go" on the display
- Start the engine, the start of the measurement data acquisition
- Check the display
4.2 STARTING MODE FUNCTION
STARTING mode
batteries and the starter provides the current required to start the
vehicle if the battery does not have su cient capacity. If the vehicle
battery is completely run down, it is advisable to perform a precharge
.
cycle before proceeding.
below! Always prevent the black and red clamps from touching
each other or a common cable!
(12V/24V
- turn the vehicle ignition to the start position for no more than 3
and the
.
- if the vehicle or boat does not start, wait at least 15 seconds
- if the vehicle or boat still does not start, wait at least 1 minute
Procedure
- Insert the starter cable connector into the relative socket (Fig. A-10).
- Press and hold button
- Make sure that the vehicle or boat to be started is switched o
- Connect the red clamp POS. (+) to the battery terminal POS. (+), then
(12V/24V
- Wait for the automatic selection or press button
- The message "Go" on the display
- 5 -
the accessories at maximum level (air conditioning, radio, etc.).
- "OK" - CHARGING POSITIVE;
- "SUF" - SUFFICIENT CHARGE;
- "BAD" - INSUFFICIENT CHARGE.
repeatedly, to check the starter capacity of the
vehicle battery
.
(switch or ignition key in the OFF position).
connect the black clamp NEG. (-) to the vehicle chassis or the vehicle
battery terminal NEG. (-) if not previously connected.
to select the battery voltage
model only).
starting is on stand-by.
process is indicated by the symbol
vehicle battery test results:
- "OK" - STARTING CAPACITY OK;
- "SUF" - SUFFICIENT STARTING CAPACITY;
- "BAD" - INSUFFICIENT STARTING CAPACITY.
is available for vehicles with 12V and 24V
WARNING:
meticulously, and always in the order given
WARNING: failure to follow these rules may compromise
the operating life of the starter:
seconds;
before trying again;
before trying again.
START mode
.
(switch or ignition key in the OFF position);
connect the black clamp NEG. (-) to the vehicle chassis or the vehicle
battery terminal NEG. (-) if not previously connected; the message
"Go" appears on the display
battery voltage
(12V/24V model only).
starting is on stand-by;
for the alternator test result:
(12V/24V
indicates vehicle
.
for the starting capacity of the
follow
these
instructions
for at least 2 seconds to select the
;
to select the
indicates vehicle