Applications; Product Description; Technical Data And Dimensions; Transport - dreno Kappa K 040-075 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

3. APPLICATIONS

This manual refers to Kappa drainage pumps, that can be used in murky water containing abrasive particles of sand
and clay, shavings and other potentially abrasive objects.
Do not use the pump in areas where there is a risk of fire or explosion or for pumping flammable liquids.
The pumps comply with the EU machinery directive, see data plate. The manufacturer guarantees that a
brand new, totally or partially submerged pump, under normal operating conditions, does not produce
noise exceeding 70db(A).
Do not use the pump if it is partially disassembled
WARNING!
If a person comes into contact with the pump or the immediate area nearby (construction site or
agricultural excavations), a differential switch on the phases (GFI) must be used in addition to the earth
conductor coming out of the pump. In the case of pumping near jetties, beaches, banks or fountains,
a minimum distance of 20 meters between the pump and any people in the water must be kept.
WARNING!
The pump cannot be installed directly in swimming pools. When used in communication with swimming
pools, special regulations must be complied with

4. PRODUCT DESCRIPTION

Limitations
Immersion depth: 20m max.
Fluid temperature: 40°C max.
Motor. Three-phase asynchronous motor short-circuited for 50 Hz. IP68 protection.
Motor protection. Pumps with built-in protection are provided with protections that disconnect the voltage at high
temperature. Alternatively, the thermal protections can be connected to a protection device to be provided within
the control panel.
Electrical cable: 20 m H07RNF or equivalent. In case of a longer cable, consider the voltage drop.
Materials used
The construction materials of the components have been chosen with particular care to obtain high reliability and
durability even in the most demanding applications. The parts that make up the Kappa series electric pumps are in
aluminium alloy. The hydraulic parts are rubber coated, the impeller is made of very hard steel, the shell is in
stainless steel. For the K040 and K 075 models the components are in GG25 cast iron.

5. TECHNICAL DATA AND DIMENSIONS

Technical data and dimensions can be found at the end of this manual.

6. TRANSPORT

The pump can be transported and stored in a horizontal or vertical position. Check that it is secured properly and
cannot roll.
The pump must always stand on a solid surface so as not to tip over. This applies to transportation, testing
and installation.
WARNING!
Always protect the end of the cable to prevent the access of moisture. Otherwise the water may enter the
cable entry compartment or the motor through the cable.
WARNING!
Always use the handle to lift the pump. Do not grip the cable or the hose. In case of prolonged storage,
protect the pump from dirt and heat. After prolonged storage, inspect the pump and turn the impeller
manually before commissioning. Above all, check the seals and the electric cable with its cable gland.
WARNING!
ENGLISH
11
Tabla de contenido
loading

Tabla de contenido