ENGLISH
The module is provided with 2 independent relays.
It can also be used to break phase and neutral of
one device (see page 14).
Electric characteristics
• Powered by Bus: 4 CU (using all the 2 relays)
• Bus terminal configurable by means of dip-switch:
TERM
• Relay outputs:
- 230 V~ / 16 A on resistive load
- Use of high inrush current relays (80 A)
- Max. current per output: 16 A
• Five terminals for 2+2 buttons for direct, local
operation of the relay output in toggle mode only
(**)
P1 and P2 operate relay 1, P3 and P4 operate
relay 2.
(*)
In detail: CU = 0.5 + 1.75 x N, where N is the number of used
relays (N=1,2)
(**)
Max distance: 70 m
6
Logic characteristics
• Configurable with IperSet software, via USB (see
1071/56)
• 254 logical addresses available
• Each single relay can be configured as NO
(default) or NC
• Activation of each single relay by 39 events max.
(*)
(sensors or push buttons)
• 40 logic Actions available for each single relay:
- 25 standard Actions: Immediate, On, Off,
Toggle, retriggerable stair light Timer, normal
Timer, delayed switch-off, delayed switch-on,
blinking effect, double operation with and
without timer etc.
- 5 Inhibit Actions, from switch or push button
- 5 Forced ON Actions in case of alarm
- 5 Forced OFF Actions for an upper level
hierarchical management
DS1071-022