PUMP TO HOUSE CONNECTION (DISCHARGE PIPE)
2. Wrap thread tape around the tank inlet
threads on pump/tank (A). Insert tank hose
gasket (AA) into the inlet of tank hose (B).
Using wrench, tighten tank hose (B) onto tank
inlet.
3. Wrap thread tape around the threads of a
1 in. discharge tee (not included). Using a
pipe wrench, thread the 1 in. discharge tee
into the 1 in. opening in the top of the tank
tee.
4. Install a 1 in. MPT x 1/4 in. FPT galvanized
bushing and (optional) pressure gauge (both
not included), or a pipe plug (not included). Do
not tighten, as you will prime pump/tank (A)
later at this location.
5. Wrap thread tape around the threads of a 1 in.
male PVC adapter (not included) and thread
the adapter into the discharge tee.
2
B
3
1 in.
Discharge Tee
4
Pressure Gauge
or Pipe Plug with
Bushing
5
1 in. male
PVC adapter
10
A
AA
Tank
Inlet
Tank Tee
1 in.
Discharge Tee
1 in.
Discharge Tee