D1
Data connection to reader.
L2
Open collector output to control reader LED.
L1
Open collector output to control reader LED.
BZ
Open collector output to control reader beeper if fitted.
Specifications
Power supply
Current consumption without reader
Reader power output (depending on
RDR link setting)
Reader output current for 2 s
Constant
Relay contact ratings:
Max. current
Max. voltage
Dimensions (H x W) (size B board)
Cable
Regulatory information
Manufacturer
PLACED ON THE MARKET BY:
Carrier Fire & Security Americas Corporation Inc.
13995 Pasteur Blvd
Palm Beach Gardens, FL 33418, USA
AUTHORIZED EU REPRESENTATIVE:
Carrier Fire & Security B.V.
Kelvinstraat 7, 6003 DH Weert, Netherlands
Product warnings
THESE PRODUCTS ARE INTENDED FOR
and disclaimers
SALE TO AND INSTALLATION BY QUALIFIED
PROFESSIONALS. CARRIER FIRE &
SECURITY CANNOT PROVIDE ANY
ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY
"AUTHORIZED DEALER" OR "AUTHORIZED
RESELLER", IS PROPERLY TRAINED OR
EXPERIENCED TO CORRECTLY INSTALL
FIRE AND SECURITY RELATED PRODUCTS.
For more information on warranty disclaimers and
product safety information, please check
https://firesecurityproducts.com/policy/product-
warning/
Certification
Carrier Fire & Security hereby declares that this
device is in compliance with the applicable
requirements and provisions of the Directive
2014/30/EU and/or 2014/35/EU. For more
information see www.firesecurityproducts.com or
www.aritech.com
REACH
Product may contain substances that are also
Candidate List substances in a concentration
above 0.1% w/w, per the most recently published
Candidate List found at ECHA Web site.
Safe use information can be found at
https://firesecurityproducts.com/en/content/intrusi
on-intro
2 / 16
12 V
45 mA max.
+5V to +12 V
5V
max. at 100 mA
5V
at 75 mA
0 to 30 V
at 1 A
48 V
at 300 mA
80 x 52 mm
Cat. 5 UTP data cable.
Max. length 50 meters
or scan the QR code.
2012/19/EU (WEEE directive): Products marked
with this symbol cannot be disposed of as
unsorted municipal waste in the European Union.
For proper recycling, return this product to your
local supplier upon the purchase of equivalent
new equipment, or dispose of it at designated
collection points. For more information see:
recyclethis.info
Contact information
www.firesecurityproducts.com or www.aritech.com
For customer support, see www.firesecurityproducts.com
DA: Installationsvejledning
Montering
Printkortet ATS1170 kan monteres i alle eksisterende
centralkabinetter som støtter B-modul print B.
Dip-switch for RAS
Se figur, punkt 1.
Adressering: Dip-Switch 1 til 4 bruges til at indstille RAS-
adressen. Se også iinstallationsmanualen for ATS-
Centralenhenden.
DIP-switch
Se figur, punkt 2.
ON: Enheden er den sisdte fysiske enhed på databussen (term).
T
OFF: Enheden er IKKE den siste fysiske enhed på databussen.
A
ON: Aktiver offline programmeringsmodus.
OFF: Deaktiver offline-programmering. Brug denne indstillingen
for normal drift.
B
ON: Aktiver standard bank- og kreditkort med magnetstripe.
OFF: Aktiver magnetkort i ATS-format.
ON: Magnetstripelæser bruges.
C
OFF: Wiegand-læser bruges.
Tilkobling til ATS-databuss (system eller
lokalt) og jording
Se i installationsmanualen for ATS-centralenheden.
Tilslutninger J2 og J3
J2: PWR 12 VDC indgang til forsyning samt Data positiv og
negativ til kommunikation via databussen.
J3: Relæ til el-lås (NO/C/NC). Dette relæ vil være aktiveret i
den tid døren er låst op, samtidig vil udgangen L1 eller L2
pulse. Se i programmeringsmanualen for ATS centralen om
denne type RAS udgangskontrolgruppe
(programmeringsmenu 3).
LED's
RX: LED blinker for at angive, at der modtages polling via
databussen fra ATS-central. Hvis LED'en ikke blinker, er
P/N MAINST-ATS1170 (ML) • REV E • ISS 14DEC20