8.6 Radio sensor test
This procedure allows to test the correct functioning of the radio sensor. This operation must be carried out
with the radio sensor on position of normal functioning.
Press the test key of the sensor.
1
Light up the light sensor.
2
Make vigorously rotate the wind
3
sensor
Adjust the desired sun and wind thresholds
4
with the two trimmers present in the sensor.
9. Total reset of the control unit's memory
1) Cut off power supply to the control unit.
2) Press and keep pressed the learning key while you give again tension to the control unit. After 7 seconds
the control unit emits a continuous beep.
3) Release the learning key, all the transmitters have been erased and the settings have been reset at
factory settings.
GUARANTEE - In compliance with legislation, the manufacturer's guarantee is valid from the date stamped on the product
and is restricted to the repair or free replacement of the parts accepted by the manufacturer as being defective due to poor
quality materials or manufacturing defects. The guarantee does not cover damage or defects caused by external agents,
faulty maintenance, overloading, natural wear and tear, choice of incorrect product, assembly errors, or any other cause not
imputable to the manufacturer. Products that have been misused will not be guaranteed or repaired.
Printed specifications are only indicative. The manufacturer does not accept any responsibility for range reductions or
malfunctions caused by environmental interference. The manufacturer's responsibility for damage caused to persons
resulting from accidents of any nature caused by our defective products, are only those responsibilities that come under
Italian law.
6-1622111
rev.1
18/09/2012
ITA
The control unit emits one beep until the
release of the test key. Correct functioning.
The control unit does not react. Check the
sensor (distance, power supply..) and check
that
memorized (see 8.5)
The automation opens itself. Correct
functioning.
The automation closes itself. Check the
rotation sense of the motor and the
electrical connections.
The automation closes itself. Correct
functioning.
The automation opens itself. Check the
rotation sense of the motor and the
electrical connections.