7. AWNING/SHUTTER selection
The control unit is supplied with awning factory configuration.
To select the typology of installation proceed as follows
Press and keep pressed the reset/learning
key present on the card for almost 10
1
seconds.
Release the reset / learning key present on
2
the card.
Select the desired typology by 10 seconds
as follows:
Press UP (radio) to select the
3
AWNING typology.
Press DOWN (radio) to select the
SHUTTER typology.
NOTE: the maximum time for the selection is of 10 seconds, more than the phases ends and the typology
remains unchanged.
8. SUN – WIND radio climatic sensor
The control unit allows to utilize a sun – wind sensor radio type. The control unit integrates the reception of
the radio signal with special protocol and identifies and handles the radio sensor.
Since the meteorological sensors impose the opening or closing of the shutter, it is of fundamental
importance to select the correct sense of motor's rotation.
8.1 SUN radio sensor
The control unit is realized in way to carry out the opening of the shutter on the occasion of the transition
night to day, while it realizes the closure of the shutter to the luminosity transition day to night. Moreover
the re – opening for light has been integrated at the end of eventual alarms (wind or disconnection).
8.2 Deactivation light sensor
It is possible to deactivate the light sensor functionality in any moment and consequently do not make
automatically go up and down the automation as function of the light variation. To deactivate the light
sensor proceed as follows:
Press and keep pressed a transmitter's
1
key (almost for 8 seconds).
Release the key
2
6-1622111
rev.1
18/09/2012
ITA
The control unit emits 2 beep to indicate
the deactivation of the sensor.
The control unit emits 3 beep to indicate
the reactivation of the sensor.
ENG
FRA
ESP
DEU
The control unit emits ONE
beep
The control unit emits a
series of short beep.
The control unit emits 3 short beep
to indicate the AWNING typology.
The control unit emits 2 short beep
to indicate the SHUTTER
typology.
POR
4/8