WARNING: DO NOT INSTALL THE CONTROL UNIT
1. Introduction
The control unit "MICRO CAP SENS" has been studied to be utilized with shutters and awnings. This control
unit contains a radio receiver for the remote control by transmitters (transmitters type CLARUS and B.RO)
and to the radio sensor (WINDUO RADIO type). The control unit has been realized with small dimensions to
be installed inside the shutters' boxes or outside (respecting the orientation of the control unit).
To simplify the installation, the 230V power supply is supplied with three cables and it is possible to connect
a motor with 500W maximum power to the cables getting out from the control unit.
2. Configuration
Radio
module
Relay 7A
Buzzer
Learning
button
4. Installation
For an external installation, is indispensable to respect the orientation of the control unit. The correct
installation is with the power supply cables and the motor's cables getting out from the down as reported on
the box.
Correct installation
5. Modality of relay's activation
The relays are activated with a control "UP" or "DOWN" and are deactivated pressing the "STOP" key, or
giving a control in the opposite sense, UP when the automation goes down or vice versa.
6-1622111
rev.1
BEFORE READING THE INSTRUCTIONS
18/09/2012
ITA
ENG
FRA
ESP
DEU
3. Electrical connections
DOWN / BLACK
UP/ BROWN
M
COMMON / BLUE
GND / GREEN-YELLOW
Warning:
the
functions
depend on the orientation of the
motor. If at one up control (up)
corresponds a descent (down), it will
be necessary to invert the brown cable
(up) and the black cable (down).
UNCORRECT installation