2.6 Product overview
Mains connection
*
only control variant DDE-PR/P
Fig. 2
Overview
3. Technical data / Dimensions
3.1 Technical data
Data
Turn-down ratio (setting range)
Max. dosing capacity
Min. dosing capacity
Max. operating pressure
Mechanical
data
Max. stroke frequency
Stroke volume
Accuracy of repeatability
Max. suction lift during operation
Max. suction lift when priming with wet valves
Min. pressure difference between suction and
discharge side
10
Valve, discharge side
Operating elements
(Section 6.1)
Deaeration valve
(Section 5.3)
Capacity
adjustment knob
Dosing head
Keys* and status LED
deaeration hose
Mechanical lock
Drain opening in
case of diaphragm
Signal
inputs/outputs*
(Section 4.3)
1)
Connection,
breakage
Mounting plate
[1:X]
[l/h]
[gph]
[l/h]
[gph]
[bar]
[psi]
[strokes/min]
[ml]
[%]
[m]
1)
[m]
[bar]
Valve, suction side
6-10
15-4
1000
1000
6.0
15.0
1.5
4.0
0.006
0.015
0.0015
0.0040
10
4
150
60
140
180
0.81
1.58
± 5
6
2
3
1