Warning
Prior to installation, read these installation and
operating instructions. Installation and operation
must comply with local regulations and accepted
codes of good practice.
1. Symbols used in this document
Warning
If these safety instructions are not observed, it may
result in personal injury.
If these safety instructions are not observed, it may
Caution
result in malfunction or damage to the equipment.
Notes or instructions that make the job easier and
Note
ensure safe operation.
2. General information
These installation and operating instructions are a supplement to
installation and operating instructions for standard CR, CRN
pumps, publication No 99078486.
3. Product description
The Grundfos air-cooled top separates the seal chamber from the
chamber stack by an air-cooled chamber.
Before reaching the shaft seal, the hot liquid is cooled to a
temperature of +120 °C or lower (at a maximum liquid
temperature of +180 °C when flowing through the air-cooled
chamber.
4. Applications
The air-cooled top is available for the following Grundfos pumps:
Pump type
CR 95
●
●
● Available.
Page
5
5
5
5
5
5
5
6
6
6
7
8
8
8
8
CR 125
CR155
●
●
●
●
5. Temperature range
The air-cooled top is available for three different temperature
ranges:
Material of
Liquid temperature [°C]
rubber parts
Water-based liquids
120-150
EPDM
120-180
FXM/EPDM
Thermal oils
120-240
FKM
120-180
FKM
6. Vent positions
6.1 Vertical pumps
Fig. 1
Vent positions on vertical CR pumps
6.1.1 Dimensions
Fig. 2
Dimensional sketch
Key to fig.
2
Pump type
CR, CRN 95, 125, 155
(5.5 - 7.5 kW)
CR, CRN 95, 125, 155
(11 - 22 kW)
CR, CRN 95, 125, 155
(30 - 37 kW)
CR, CRN 95, 125, 155
(55 kW)
PN
CR
25
95-155
25
95-155
16
95
16
125-155
x [mm]
220
245
270
320
5