Target Group; Intended Use; Power Supply - Techem 4.1.2 Manual De Operación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 126
OPERATING INSTRUCTIONS
Important information

Target group

• Qualified craftsmen
• Specialist personnel trained by Techem

Intended use

The ultrasonic energy meter type 4.1.2 serves exclusively the physically correct data
collection of energy consumption. The meter is an energy meter for universal use in sys-
tems for heat and cold measurement. The meter is suitable for water circulating in heating
systems (water without additives, exceptions: see AGFW FW510).
If a sealing or user lock of an installed meter is damaged or removed by a person not com-
missioned by Techem, this meter can no longer be used for legally compliant consumption
recording and the calibration may become invalid.
Safety and hazard information
Ö The regulations for the use of energy meters must be observed.
Ö The piping system must be fully earthed.
Ö Lightning protection must be guaranteed via the house installation.
Ö Clean the meter only from the outside using a soft, damp cloth.

Power supply

Lithium battery 3.6 V (not a hazardous good), designed to last for the service life of the
meter.
Cannot be replaced.
Device properties
The energy meter is available in the following versions:
• Heat meter for heat energy measurement ( ) 
• Cold meter for cold energy measurement ( ) 
• Combination meter for the combined heat and cold energy measurement (heat with
declared conformity) (
• The computer unit is detachable.
• Temperatures will be measured every 32 seconds. Special variant with 4-seconds tem-
perature measuring rate available, with restrictions.
• Programming and read-out possible via TAVO.
Adjustable device properties when commissioning:
• Installation location of the volume measuring section in the inlet (
outlet (
) (see display).
!
The device properties can only be changed during commissioning. An energy
progress of 10 kWh or 0.036 GJ is considered a locking condition. Afterwards,
the device properties can no longer be changed.
16
/
) 