IMG STAGELINE UVBG-400 Manual De Instrucciones página 2

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 5
UVBG-400
Order No. 38.2610
GB
High-Intensity UV Spotlight
Please read these operating instructions carefully
prior to the installation and keep them for later use.
1 Applications
This UV spotlight generates closely focussed
black light and can be used in an optimum way
for creating effects on stage, in discothèques,
clubs, bars or at events. The invisible UV radia-
tion exites fluors (e. g. white areas and material
fibres, black light luminous colours) to emit light.
2 Safety Notes
This unit corresponds to all required directives of
the EU and is therefore marked with
WARNING The unit is supplied with hazard-
ous mains voltage (230 V~).
Leave servicing to skilled person-
nel only. Never make any modifi-
cation not described in this
instruction manual. This may
cause an electric shock hazard.
It is essential to observe the following items:
The unit is suitable for indoor use only. Protect
it against dripping water and splash water,
high air humidity, and heat (admissible
ambient temperature range 0 – 40 °C).
Do not place any vessels filled with liquid, e.g.
drinking glasses, on the unit.
During operation the unit will become very
hot. Do not touch it during operation and let it
cool down for a few minutes after switching off
before touching it.
Do not set the unit into operation, and imme-
diately disconnect the mains plug from the
mains socket if
1. there is visible damage to the unit or to the
mains cable,
2. a defect might have occurred after a drop or
similar accident,
3. malfunctions occur.
The unit must in any case be repaired by
skilled personnel.
A damaged mains cable must only be re-
placed by the manufacturer or by authorized,
skilled personnel.
Never pull the mains cable to disconnect the
mains plug from the mains socket, always
seize the plug.
1
4
5
®
Copyright
For cleaning only use a dry, soft cloth, by no
means water or chemicals.
No guarantee claims for the unit and no liabil-
ity for any resulting personal damage or mate-
rial damage will be accepted if the unit is used
for other purposes than originally intended, if
it is not correctly installed or not repaired in an
expert way.
Important for U. K. Customers!
The wires in this mains lead are coloured in
accordance with the following code:
green / yellow = earth,
blue = neutral,
brown = live
As the colours of the wires in the mains lead
.
of this appliance may not correspond with the
coloured markings identifying the terminals in
your plug, proceed as follows:
1. The wire which is coloured green and yel-
low must be connected to the terminal in the
plug which is marked with the letter E or by
the earth symbol
green and yellow.
2. The wire which is coloured blue must be
connected to the terminal which is marked
with the letter N or coloured black.
3. The wire which is coloured brown must be
connected to the terminal which is marked
with the letter L or coloured red.
WARNING: This appliance must be earthed.
If the unit is to be put out of opera-
tion definitively, take it to a local
recycling plant for a disposal which
is not harmful to the environment.
3 Inserting a Lamp
The unit is supplied without UV lamp. A high-
pressure mercury vapour lamp 230 V~/400 W
with base E 40 (e. g. UVBGB-400 from the pro-
duct range of "img Stage Line") is required.
Never use a lamp with a higher wattage than
400 W!
WARNING
Always disconnect the mains
plug before inserting or removing
the lamp.
The lamp heats up very much during operation.
Let it cool down for 5 minutes as a minimum
after operation of the unit before replacing it.
2
©
by MONACOR INTERNATIONAL GmbH & Co. KG, Bremen, Germany. All rights reserved.
, or coloured green or
3
4
1) Unscrew the two lateral recessed head
screws (see arrows) at the protective grid (3)
and remove it.
2) For handling the lamp, use a clean, soft cloth,
the glass bulb should not be touched with
your fingers. Screw the lamp into the lamp-
holder.
3) Screw down the grid. Never operate the unit
without protective grid!
4 Mounting
The place of mounting must be chosen so that a
sufficient air circulation is ensured during opera-
tion. Pay in any case attention to a sufficient
distance to easily flammable material or material
sensitive to heat.
The distance to illuminated objects must
be 2 m as a minimum.
1) Mount the unit with a support for light effect
units (C-hook) or a stable mounting screw via
the bracket (1) to a cross arm or a stand.
WARNING The unit must be mounted in a
safe and expert way. If it is
installed as a suspended load
above persons, it must addi-
tionally be secured, e. g. by a
safety rope. Guide the safety
rope through the safety lug (2)
and fix it in such a way that the
maximum falling distance of
the unit is 20 cm.
2) To align the unit, slightly release the two
screws (4) at the bracket, incline the unit as
desired, and retighten the screws.
5 Setting into Operation
WARNING – UV radiation!
During operation, high UV radia-
tion occurs very close to the lamp.
With increased sensitivity of the
skin to UV light, keep a distance.
To prevent eye damage by UV
light, never look directly into the lit
lamp.
To switch on the unit, connect the mains plug (5)
to a mains socket (230 V~/50 Hz), disconnect it
for switching off. After switching on, the lamp
needs approx. 3 to 4 minutes until it will reach its
full luminous power.
For a more convenient operation it is recom-
mended to connect the unit to a mains socket
which can be switched on and off via a light
switch.
Note: If the unit is disconnected from the mains
for a short time only and then set into op-
eration again, the lamp does not light up
again immediately. It must first cool down
(5 to 10 minutes) to be able to restart.
6 Specifications
Power supply: . . . . . 230 V~/50 Hz
Power consumption: . 650 VA
UV lamp: . . . . . . . . . . high-pressure
mercury vapour lamp
230 V~/400 W
with base E 40
Dimensions: . . . . . . . 31 x 31 x 34.5 cm
Weight: . . . . . . . . . . . 9 kg
Subject to technical modification.
A-0559.99.01.03.2006