TROUBLESHOOTING
Symptoms
1
The indicator
2
The indicator
The indicator
3
sing the button
4
The indicator
blinks.
TECHNICAL TABLE
1
Reference
2
Rated power supply voltage
3
Rated power
4
Energy efficiency
5
Rated voltage output
6
Rated voltage output
7
Rated battery capacity
8
Battery consumption when idle
9
Undulation
10
Charging curve
11
Operating temperature
12
Storage temperature
13
Protection rating
14
Protection class
15
Noise level
16
Weight
17
Dimensions (L x H x D)
18
Standards
12
"• Polarity reversal
• Battery voltage is too high
blinks.
• Clamps in short-circuit"
Charge failure, battery non recoverable.
is on.
stays on even after pres-
Thermal protection.
Charger in sleep mode.
GYSFLASH 6.12 XL
Causes
Remedies
Check that the clamps are properly connected.
Change the STARTPACK 12.24 XL batteries.
Ambient temperature is too high (>50°C), cool the
room and let the charger cool down.
Press the button
or connect the STARTPACK
12.24 XL to the charger to exit sleep mode.
GYSFLASH 6.12 XL
~ 220-240 VAC 50 / 60 Hz
190 x 100 x 52 mm
EN
99615
90 W
> 89 %
12 VDC
6:00 AM
14 – 110 Ah
< 0.5 mA
< 150 mV rms
IUOU
0°C – +50°C
-20°C – +80°C
IP65
Class II
< 50dB
0.79 Kg
"EN 60335-1
EN 60335-2-29
EN 62233
CEI EN 60529
EN 50581
EN 55014-1
EN 55014-2
CEI 61000-3-2
CEI 61000-3-3"