Bosch Rexroth SD301 Manual Del Usuario página 46

Ocultar thumbs Ver también para Rexroth SD301:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 96
46/144 Bosch Rexroth AG
6 Menus when connecting the SD301 to a KE31x
An unacknowledged error is identified by an
inverse display of the error code and error
class (see Fig. 39).
6.2.1
Error List
The KE31x errors are listed under this menu
option (Fig. 40).
From Version V1.4 onward, you must log on
again before acknowledging an error.
Fig. 40:
6.2.2
Tightening Cell Error
The unacknowledged errors from all compo-
nents in a tightening cell are listed under this
menu option (Fig 41).
Fig. 41:
Class 3 errors can be directly acknowledged
via the SD301 by pressing the acknowledge
button.
SD301 | 3 609 929 826/06.03
6.2.3
Sequence test
The KE is controlled via the SD301 using the
sequence test. External control via a partner
controller is suppressed in this mode.
Sequence tests via the SD301 are
only possible when logged on (see
section 4.4)!
1
2
KE
App
o
App
Loosen
App
App
test 1
App
Rework
App
synch. tightening
Fig. 42:
Pressing the Application selection (1) button
calls up a list of the available tightening appli-
cations in the display field; the application
currently selected is highlighted (Fig 42).
Pressing the required application number se-
lects the application; the actual values of the
last tightening job are displayed (Fig. 43).
Fig. 43:
3
4
5
Tabla de contenido
loading

Tabla de contenido