II. Solenoid valve (12 V DC)
1. Remove screw (K) using a 2.5mm allen key and remove
housing (L), see fold-out page III, Fig. [10].
2. Remove screws (O1) and detach retaining plate (O).
3a. Detach plug-in connector (P) and remove solenoid
valve (R) by turning clockwise using a 5mm allen key,
see Fig. [11].
3b. Remove plug-in connector (P) and pull out solenoid
valve (R).
4. Remove filter (T).
Observe the correct installation position.
Assemble in reverse order.
Insert plug - in connector (P) into bore (P1), see Fig. [11].
III. Filter
1. Unscrew connection hose and remove adapter (A),
see Fig. [12].
2. Remove filter (B).
Assemble in reverse order.
Fault/cause/remedy
Fault
Cause
Water not flowing
• Water supply interrupted
• Filter upstream of solenoid valve blocked
• Solenoid valve defective
• Plug-in connector of solenoid valve
without contact
• No voltage
Water flows
• Solenoid valve defective
continuously
Undesired water flow
• Detection range of sensor system set too
high for local conditions
• Erroneous activation due to object within
detection range of sensor system
Water quantity too
• Filter or mousseur dirty
low
• Service valves not fully open
• Water supply restricted
Incorrect mixed
• See "Water quantity too low"
temperature
• Limescale on mixer spindle
• Incorrect setting of temperature limiter
IV. Unscrew and clean aerator (42 832), see fold-out page I.
Assemble in reverse order.
V. Mixer spindle
1. Disconnect fitting from connections.
2. Remove fitting from basin.
3. Remove screw (E) using a 2mm allen key, see Fig. [13].
4. Remove mixer spindle (F).
5. Pull off stop ring (G).
6. Remove screw (U) from housing using a 2.5mm allen key.
7. Pull out mixer spindle (H), inspect, clean and replace if
necessary.
Assemble in reverse order, see section "Setting the
temperature limiter".
Screw (U) must engage in groove (H1) of mixer spindle (H).
Replacement parts, see fold-out page I ( * = special
accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.
Remedy
- Open shut-off valves, service valves
- Clean, see "Solenoid valve maintenance"
- Replace, see "Solenoid valve maintenance"
- Attach plug-in connector
- Switch on power supply, check plug-in connectors
- Replace, see "Solenoid valve maintenance"
- Reduce range using remote control (special
accessory, Prod. no.: 36 206)
- Install base (special accessory, Prod. no.: 36 210)
- Replace, see maintenance Filter (III) and
Mousseur (IV)
- Fully open shut-off valves, service valves
- Check supply lines, open service valves
- Clean, see "Mixer spindle maintenance"
- Adjust, see description
6