Control Panel - KBS KU 711 Manual De Instrucciones

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 31
12 - EN
 KEYPAD and ASSOCIATED FUNCTIONS
ON/STAND BY
Press this button for a few seconds to switch the appliance on and off.
It can be switched on and off remotely via the multifunction input (if
present).
MANUAL DEFROSTING
Press this button for a few seconds to activate manual defrosting, if the
temperature of the evaporator allows it and provided that the Overcooling
function is not activated.
If the defrosting time interval elapses while Overcooling is in progress, the
former will be activated upon conclusion of the latter.
CHAMBER LIGHT if parameter u1=0
Press the auxiliary button to switch the chamber light on and off
manually.
The chamber light can be switched on and off automatically via the micro
port input.
DOWN button
This scrolls the menu items and decreases the values.
When pressed for a few seconds, the Overcooling function is activated
unless defrosting or dripping is not in progress or the evaporator fan is
stopped.
During Overcooling, the working set point is decreased to the temperature
and for the time set by the parameters.
UP button
This scrolls the menu items and increases the values.
When pressed for a few seconds, the low RH% function ("rhL" appears
on the display) or the high RH% function ("rhH" appears on the display)
is activated for 10 seconds.
If the function is not available and the button is pressed, "----" will appear
on the display.
SET POINT
This provides access to the set point edit function.
UN/BLOCKING THE KEYPAD
The keypad is blocked by keeping
few seconds: "Loc" will appear on the display.
Pressing them once again will unblock the keypad: "UnL" will appear on the
display.
STOPPING THE BUZZER (if present)
Briefl y press any button.

CONTROL PANEL

and
pressed simultaneously for a
 INDICATORS
LED
MEANING
ON
The compressor is on
FLASHING
The working Set Point is being changed
Compressor protection in progress
ON
Defrosting in progress
FLASHING
Defrosting requested but compressor protection is in
progress
Dripping in progress
Heating coolant in progress
ON
The evaporator fan is on
FLASHING
The evaporator fan is being stopped
ON
Chamber light switched on manually
FLASHING
Chamber light switched on automatically
ON
The anti-steaming up resistors will be switched on
Auxiliary output switched on manually
Alarm output activated
The door resistors will be switched on
The evaporator valve will be activated
FLASHING
Auxiliary output switched on remotely
ON
Overcooling in progress
ON
Alarm or error in progress
ON
Not all the information regarding the HACCP alarms has
been displayed
FLASHING
At least one new alarm has been saved
OFF
All the information regarding the alarms has been displayed
List of the HACCP alarms has been deleted
ON
Energy Saving in progress
ON
Compressor maintenance required
ON
The temperature measurement unit will be degrees Celsius
ON
The temperature measurement unit will be degrees Fahrenheit
ON
The instrument is on stand-by