Technical Data
Operating pressure:
Recommended operating pressure:
MPa
Test pressure:
(1 MPa = 10 bars = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Connections G ½":
Rate of flow:
XXX = Colors
000 chrome plated
420 platinum
Test certificate
DVGW
10
Hansgrohe · Postfach 1145 · D-77761 Schiltach · Telefon +49 (0) 78 36/51-1282 · Telefax +49 (0) 7836/511440
English
max.1 MPa
0,1 – 0,5
1,6 MPa
max.80° C
65° C
cold right - hot left
P-IX
SVGW
E-Mail: [email protected] · Internet: www.hansgrohe.com
Spare parts see page 3
1
handle
2
flange for cold water
3
flange for hot water
4
flange
5
spout cpl.
6
diverter knob
7
aerator cpl.
8
selector assy
9
hand shower
10
filter packing (25)
11
flange for shower holder
12
shower holder, assy
13
hose 2,00 m
14
non return valve DW 15
15
shut off unit, cold
16
shut off unit, hot
ACS
NF
39294XXX
96772XXX
96771XXX
96782XXX
96773XXX
96774XXX
13956XXX
96775000
38850XXX
94246000
94052XXX
92380XXX
94148000
94074000
94008000
94009000
WRAS
KIWA