Installation to Wall
When fixing the heater to a wall, ensure hinges are in the underside so that the lid hands
down in the open position.
•
Minimum required distances:
a
500 mm from the side wall
b
500 mm from the ceiling
c
Installation height above 1.8 m.
•
The heater must be fixed to a wall with the bracket supplied to allow adequate ven-
tilation.
•
Never fix or place heater near flammable or combustible materials.
•
Generally heaters must be placed at a safe distance (clear space) of at least 2.0
m from combustible materials and glass walls. If installed in workshops or garages
where inflammable or combustible paints are used, the heaters must be installed at a
distance of at least 4.0 m from the source of danger.
•
If the heaters are placed in areas where spray painting of any description is taking
place, they should not be used during the painting operations.
•
Never use the heater in particularly dusty and explosive areas.
Connection to 220-240 Volts Power Supply
•
It is important to ensure that the electricity supply is of adequate capacity for the
electrical load required by the appliance being installed.
•
These appliances must be earthed.
16