Wear Parts; Spare Parts; Remedy Of Faults - Oase AquaOxy 240 Instrucciones De Uso

Ocultar thumbs Ver también para AquaOxy 240:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 20
Replace membranes
 G, H, I
N O T E
• Never operate the unit with defective membranes.
• Always replace both membranes even when only one membrane is defective. The procedure is identical for both
membranes.
• Please contact your specialist dealer if you do not wish to undertake the replacement yourself.
• Undo the screws on the underside of the housing and remove the upper section of the housing together with the
sealing ring (E).
• Remove the membrane (G, 6).
• Unhook the membrane clip (G, 7).
• Undo the screw holding the membrane (H, 6) and membrane clip (H, 7).
• Fit the new membrane.
• Firmly screw the membrane (I, 6) in place with the screw of the membrane clip (I, 7).
• To prevent the screw connection from coming undone, secure by applying e.g. varnish.
• Reassemble the unit in the reverse order (H).
Storage/overwintering
When the unit is in continuous operation it can remain in place at freezing temperatures.) Otherwise store the unit in-
doors in a dry room (room temperature).

Wear parts

The following components are wear parts and are excluded from the warranty:
• Membrane
• Aeration stone

Spare parts

The use of original parts from OASE ensures continued
safe and reliable operation of the unit.
Please visit our website for spare parts drawings and spare
parts.

Remedy of faults

Malfunction
The unit is not operating
The unit does not deliver any air or the amount
delivered is insufficient
The unit is unusually loud
Disposal
N O T E
Do not dispose of this unit with domestic waste.
• Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system provided for
this purpose.
www.oase-livingwater.com/spareparts
Cause
No mains voltage
The aeration stones are soiled
The air filter is soiled
Membrane is defective
Membrane is defective
Remedy
Check mains voltage
Clean the aeration stones
Clean the air filter
Replace the membranes
Replace the membranes
- EN -
11
Tabla de contenido
loading

Tabla de contenido