EN
Model(s)
† Pressure (L
235
252, 252-EU
252-3-EU
255A, 255A-EU
255A-3-EU
258
† K
= 3dB measurement uncertanity
pA
‡ K
= 3dB measurement uncertanity
wA
Installation and Lubrication
Size air supply line to ensure tool's maximum operating pressure (PMAX) at tool inlet.
Drain condensate from valve(s) at low point(s) of piping, air filter and compressor tank daily.
Install a properly sized Safety Air Fuse upstream of hose and use an anti-whip device
across any hose coupling without internal shut-off, to prevent hose whipping if a hose fails
or coupling disconnects. See drawing 16573172 and table on page 2. Maintenance
frequency is shown in circular arrow and defined as h=hours, d=days, and m=months.
Items identified as:
1.
Air filter
2.
Regulator
3.
Lubricator
4.
Emergency shut-off valve
5.
Hose diameter
Parts and Maintenance
When the life of the tool has expired, it is recommended that the tool be disassembled,
degreased and parts be separated by material so that they can be recycled.
The original language of this manual is English.
Tool repair and maintenance should only be carried out by an authorized Service Center.
Refer all communications to the nearest Ingersoll Rand Office or Distributor.
EN-2
Sound Level dB (A)
(ISO15744)
) ‡ Power (L
p
---
---
89.7
100.7
89.7
100.7
---
---
---
---
---
---
6.
7.
8.
9.
10. Oil - Fill the Chamber
Sound Level dB (A)
(ANSI S5.1-1971)
)
Pressure
w
90.7
---
---
93.7
93.7
96.6
Thread size
Coupling
Safety Air Fuse
Oil
Vibration
Level
(ISO8662)
Power
m/s²
(ISO3744)
103.7
3.8
---
3.0
---
3.0
106.7
4.6
106.7
4.0
109.6
3.4
04584827_ed2