11
Technical specifications
Sensing range
Sensing range max.
Light spot diameter/distance
Supply voltage U
B
Output current I
max.
Switching frequency
Max. response time
Enclosure rating
Protection class
Circuit protection
Ambient operating temperature
Object with 90 % remission (based on standard white DIN 5033)
1)
2)
Limit value; residual ripple max. 5 V
3)
With light / dark ratio 1:1
4)
Signal transit time with resistive load
5)
A = U
-connections reverse polarity protected
B
C = Interference suppression
D = outputs overcurrent and short-circuit protected
11.1
Dimensional drawing
8023328.18HX | SICK
Subject to change without notice
ss
14
(0.55)
5.5
(0.22)
Ø 2.3
(0.09)
Figure 8: Dimensional drawing GTB2F
TECHNICAL SPECIFICATIONS
GTB2F-Xxx41
GTB2F-Xxx11
1 ... 8 mm
2 ... 15 mm
1 ... 9 mm
1 ... 18 mm
1)
DC 10 ... 30 V
DC 10 ... 30 V
2)
≤ 50 mA
≤ 50 mA
800 Hz
800 Hz
3)
≤ 0.625 ms
≤ 0.625 ms
4)
IP67
IP67
III
III
A, C, D
A, C, D
5)
-20 °C ... +50 °C
-20 °C ... +50 °C
3.5
(0.14)
1
(0.04)
Ø 2.2
(0.09)
2.2
(0.09)
GTB2F-Xxx31
2 ... 30 mm
1 ... 35 mm
1)
1)
DC 10 ... 30 V
2)
≤ 50 mA
800 Hz
3)
3)
≤ 0.625 ms
4)
4)
IP67
III
A, C, D
5)
5)
-20 °C ... +50 °C