2.8

Installation/dismantling work

2.9

During operation

2.10

Maintenance work

2.11

Operating fluids

10
Safety
ƒ
Wear a safety harness where required!
ƒ
At the operation site, comply with the applicable laws and regulations for work safety
and accident prevention.
ƒ
Secure and demarcate the working area.
ƒ
Keep working area free from ice.
ƒ
Remove any objects that are lying around from working area.
ƒ
Unauthorized persons must be kept away from the working area.
ƒ
If the weather conditions mean it is no longer possible to work safely, stop work.
ƒ
Work must always be carried out by two persons.
ƒ
When working at a height of more than 1 m (3 ft) above the ground, use scaffolding with
a safety harness.
ƒ
Ensure enclosed spaces have sufficient ventilation.
ƒ
Toxic or suffocating gases may build up in closed rooms or structures. Observe protective
measures according to work regulations, e.g. carry gas warning device with you.
ƒ
If there is a risk of explosion, do not carry out welding work or work with electrical de-
vices.
ƒ
Disconnect product from power supply and secure against unauthorized reactivation.
ƒ
All rotating parts must stop.
ƒ
Disinfect product.
ƒ
Secure and demarcate the working area.
ƒ
No-one is allowed in the working area during operation.
ƒ
Depending on the process, the product is activated and deactivated using separate con-
trols. The product may automatically be activated following power cuts.
ƒ
If the motor tips, the motor housing can heat up to above 40 °C (104 °F).
ƒ
A manager must be informed of any faults or irregularities immediately.
ƒ
The product must be switched off immediately if faults occur.
ƒ
The propeller must not crash into fixtures or walls. Observe the defined clearances in ac-
cordance with consulting documents.
ƒ
Observe the required water immersion. If the water level varies significantly, use level
monitoring.
ƒ
The sound pressure level depends on several factors (installation, duty point, etc.). Mea-
sure the current noise level under operating conditions. Wear hearing protection at noise
levels of 85 dB(A) and over. Demarcate the working area!
ƒ
Disconnect product from power supply and secure against unauthorized reactivation.
ƒ
Disinfect product.
ƒ
Carry out maintenance work in a clean, dry and well-lit place.
ƒ
Only carry out maintenance work described in these installation and operating instruc-
tions.
ƒ
Only use original parts from the manufacturer. The use of parts other than original parts
absolves the manufacturer of any liability.
ƒ
Immediately clean up any leakage from fluid and coolant/lubricant, and dispose of such
materials according to the locally applicable guidelines.
The seal housing is filled with white oil. The gear and the pre-chamber are filled with gear
oil.
ƒ
Wipe up leakages immediately.
ƒ
If major leakages occur, contact customer service.
ƒ
If the seal is defective, the oil enters the pumped fluid.
ƒ
Skin contact: Rinse skin areas thoroughly with soap and water. If skin irritation occurs,
consult a doctor.
ƒ
Contact with eyes: Remove contact lenses. Rinse eye thoroughly with water. If eye irri-
tation occurs, consult a doctor.