Thermador T18ID Serie Manual De Uso página 21

Ocultar thumbs Ver también para T18ID Serie:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Fault
The ice maker does not make
any ice.
Ice forms in the inflow hose
to the ice maker.
Water runs from the appliance. The water connection hose is not
The water pressure is less than
usual.
Possible cause
The ice maker is switched off.
The appliance is not supplied with
water.
Water supply has kinks.
Low water pressure.
Temperature in the freezer space is
too warm.
Ice cube container is not properly
inserted.
Incorrect shut-off tap installed.
Ice maker sensor is blocked.
Low water pressure.
Shut off tap incorrectly opened.
Temperature in the freezer space is
too warm.
properly sealed.
Incorrect shut-off tap installed.
Low water pressure.
Shut off tap incorrectly opened.
Incorrect shut-off tap installed.
Water supply has kinks.
The water filter is bunged up or used. Change the water filter.
Remedial action
Switch the ice maker on at the control
panel.
Contact the installer or the water supply
company.
Turn off the water supply at the shut-off tap.
Smoothen out the kinks, exchange where
necessary.
Connect the appliance to the stipulated
water pressure only (see chapter Connect-
ing appliance, section Water connection).
Check freezer compartment temperature
and, if required, set slightly colder.
Check the position, re-insert where neces-
sary.
Incorrect taps can cause low water pressure
and damage to the appliance.
Pull out and empty ice cube tray. Remove
ice from the sensor.
Connect the appliance to the stipulated
water pressure only (see chapter Connect-
ing appliance, section Water connection).
Open shut off tap fully.
Set temperature slightly colder in the freezer
compartment.
Replace the hose with a manufacturer's
original part.
Incorrect taps can cause low water pressure
and damage to the appliance.
Connect the appliance to the stipulated
water pressure only (see chapter Connect-
ing appliance, section Water connection).
Open shut off tap fully and check for leaks.
Check the minimum through flow.
Incorrect taps can cause low water pressure
and damage to the appliance.
Turn off the water supply at the shut-off tap.
Smoothen out the kinks, exchange where
necessary.
en-us
21
Tabla de contenido
loading

Este manual también es adecuado para:

T18if serieT24id serieT24if serieT30if serieT30bb820ss

Tabla de contenido