SCAN COMBIFLEX 450/450NS
5.4
Grinding disc replacement / assembly
Follow these steps to replace the Scan-On plate
Make sure the machine is in its "Safety off position"
Tilt the machine backwards and secure it.
Remove any tools used according to"4.14 Changing tools".
Loosen the three screws holding the Scan-On plate.
Replace the Scan-On plate.
It's recommended that new screws are used to fasten the replacement Scan-On plate.
It's also recommended that copper paste is used on the surface of the screw hole at the Scan-
On plate.
Tighten all screws by hand and make sure that they are secured.
5.5
Cleaning the machine
Before starting to clean the machine, make sure it is in its"Safety off position"
The power must not be connected while cleaning the machine.
Do not use highly pressurized water to clean the machine.
Water and soap is recommended.
5.6
Trouble shooting
5.6.1 Common faults
Symptom
Cause
The machine
There is a power failure from
won't start
The machine only
The motor is overheated
operates while
the start button is
The control device is dam-
depressed
6
www.scanmaskin.com
the power supply
aged
Correction
Inspect the fuses in the worksites
fuse box
Inspect cables
Measure that all three phases are
present and at full voltage near the
machine
Wait until the motor is cool again
Replace the control device
ENGLISH
A
6
O
E
E
O
S
63