RECOMMENDED AIR SUPPLY
No.
1
Air Tool
2
Air Hose
3
Quick Coupler
4
Oiler
5
Pressure Regulator
AIR SUPPLY
Clean and correct air pressure supply is essential for this tool. The max air pressure for this ratchet is
6.3 bar, which is the recommended limit for most air tools of this range. Check the "specifications"
section for further details. In case of decreasing air pressure caused by long hoses or other factors,
raise the air pressure accordingly to guarantee the recommended working air pressure of 6.3 bar.
Water in hose or compressor will reduce the air tools efficiency and damage it in the end. Therefore,
drain the air pressure system before each use. If the provided air pressure exceeds the
recommended limit of 6.3 bar, you will need to install a pressure regulator and gauge.
INSTRUCTION
Loosening screw connection
1. Connect ratchet with air pressure system
2. Fit suitable bit into the square drive.
3. Adjust switch on ratchet head to desired rotational direction (for most screws = counter clockwise).
4. Put ratchet with bit onto the screw and start loosening the connection by twisting the ratchet
counter clockwise MANUALLY! As soon as the screw has been loosened a bit, you can push
down the trigger lever and drive the screw out with air pressure support.
Tightening screw connection
1. Connect ratchet with air pressure system
2. Fit suitable bit into the square drive.
3. Adjust switch on ratchet head to desired rotational direction (for most screws = clockwise).
4. Put in the screw by hand and screw it in 2 or 3 turns manually.
5. Put ratchet with bit onto the screw and push down the trigger lever to screw in the screw with air
pressure support. CAUTION: Wear safety gloves and hold the ratchet firmly. The ratchet will build
up a strong torque against its rotational direction as soon as the screw has reached its dead stop.
Risk of injury caused by negligence.
Attention: After tightening, check all screws with a torque wrench to the torque specified by the
manufacturer.
BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Description
Tel.: 02196 720480
Fax.: 02196 7204820
No.
Description
6
De-Watering / Filter Unit
7
Pressure drain valve
8
Shut-Off Valve
9
Dryer / Filter Unit
10
Compressor / 11 De-Watering Valve
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed