NombreProducto
|
Installation
Airborne noise:
– For a standard machine, the noise emitted by the machine is
69 dB(A) (distance 1 m).
Safety warnings in the manual
⚠ Wa r n ing
"Warning" safety warnings could result in severe, irreversible
personal injuries or death.
⚠ Ca ut io n
"Caution" safety warnings could result in severe, reversible per-
sonal injuries.
Other warnings in the manual
Notice
"Notice" warnings could result in damage to the machine.
ℹ Information
The tables of "Information" contain advice on how to use the
machine correctly and efficiently.
2
Installation
2.1
Supply scope
Documentation:
– User manual.
– Warranty card and Declaration of Conformity.
– List of spare parts.
– Electrical circuit diagram.
Machine
Power supply cable
Drain hose
2.2
Prerequisites and preparation for
installation
Tools and material required for installation
Included in the supply:
– Power supply cable
– Drain hose
Not included for mechanical assembly:
– Flat screwdriver
– No. 10 box spanner
– Universal pliers
– Clamp
– Pressure gauge
Not included for electrical assembly:
– Power strip and/or European plug type "F" or three-phase plug
(depending on the installation)
– Electrical tester
Space required for installation
ℹ Information
Figure with machine dimensions: see appendix at the end of the
manual.
14
Check that the water line is less than 1.50 m from the intended
location of the machine.
Electrical connections
Before installation, take note of the power input required by the
▶ 6
machine. [
Technical specifications p. 21 ].
Fig. 1: Machine connection points
GP 35
A
A
A
A Water inlet ¾" GAS
B Drain pipe ⌀ 30 mm
Preparation for installation
1)
Check that the installation area is flat and stable.
2)
Check that the water line has a ¾" GAS shut-off valve at the end
closest to the machine.
3)
Check that the dynamic pressure of the machine feed water is
within the following range of values:
Dynamic water pres-
Minimum value
sure
All models
2 bar (200 kPa)
If the water pressure is higher than the maximum indicated,
install a pressure regulator to set the pressure between 2.5
and 4 bar (250 and 400 kPa).
If the water pressure is below the minimum value, install a
back-up valve.
B
C
GP 40
B C
GP 50
A
B
C
C Connection cable
Maximum value
4 bar (400 kPa)
User's manual — 2900450/0