- registration number(Fig. 2 - 4);
- job number
5. Transportation (Fig. 3)
The cabinets are fitted with a wooden support fixed to the base for handling by means of fork-lifts.
Use a manual or electrical lift truck suitable for raising the cabinet in question.
6. Receipt and first cleaning
Upon receipt of the cabinet:
- Make sure that the packaging is intact and that it is not evidently damaged;
- Unpack the cabinet with care so as not to damage the cabinet itself;
- Check each single part of the cabinet, making sure that all its components are intact;
- If anything is found to be damaged, call the supply company immediately;
- Proceed with a first cleaning using neutral products, dry with a soft cloth, do not use abrasive
substances or metal sponges, do not use alcohol or similar to clean parts in methacrylate
(plexiglass).
For correct packaging disposal. remember that it contains:
Wood - Polystyrene - Polythene - PVC - Cardbaord.
In compliance with EEC directive 94/62 we hereby approve the materials above.
7. Installation and environmental conditions (Fig. 3)
For installation, follow the instructions below:
- Do not position the cabinet:
in places containing explosive gaseous substances;
in the open air and, therefore, exposed to atmospheric agents;
near sources of heat (direct sunlight, heating appliances, incandescent lights etc.);
near air current (near doors, windows, air-conditioning systems etc.) which exceed the speed of
0.2 m/sec.
- Remove the wooden supports on the base (used for transportation) and mount the adjustable feet
(Ref. 2) regulating them so as to position the cabinet horizontally. Use a level (Ref. 1) to make sure
of its positioning.
- If the cabinet is moved, repeat the level check.
- Before connecting the cabinet to the electric supply, make sure that all the data on the nameplate
corresponds to the characteristics of the electrical system to which it will be connected.
- In order for the cabinet to operate correctly, the temperature and the relative environemntal
temperature must respect the parameters indicated in norm EN-ISO 23953 - 1/2 which provides
Climatic Class 3 (+25°C; U.R. 60%).
WARNING!:Install a maximum of 3 cabinets in line on the same power and refrigeration
channel (1 Master + 2 Slave).
N.B. All these operations should be performed by specialised technical personnel only.
8. Multiplexing of cabinets (Fig. 6)
SYDNEY 3 VCA
Pos .
Name
1 Galvanised TCEI M8x120 04711065
2 M8 Nut
3 Multiplexing kit bracket
4 Alignment plug Ø 4x80
5 Galvanised TCEI M6x60
6 Galvanised M6 nut
7 Aluminium bumper
N.B.(Fig. 7 Rif. 11) If necessary, it is possible to adjust the positioning of the uprights of the
superstructure - 9 - with the screws - 8 - and of the handle profile - 10 - with the screw - 11.
Normally these adjustments are carried out in the factory, but due to irregular multiplex
05060057 01 28/08/2015
Sydney 3 VCA-VCB-SELF-H125-H150
(Fig. 2 - 18).
MULTIPLEXING KIT
Code
04230600
02211300
02940652
04711009
04230400
01280418
..
Pos .
Pcs
4
1 Galvanised TCEI M8x120 04711065
4
2 M8 Nut
4
3 Multiplexing kit bracket
4
4 Alignment plug Ø 4x80
1
5 Galvanised TCEI M6x60
1
1
SYDNEY 3 VCB
Name
Code
04230600
02211300
02940652
04711009
English
Pcs .
4
4
4
2
1