OBSERVE ALL LOCAL CODES AND
ORDINANCES.
DO NOT, UNDER ANY CIRCUMSTANCES,
REMOVE THE POWER SUPPLY CORD
GROUND PRONG.
ELECTRICAL GROUND IS REQUIRED ON
THIS APPLIANCE.
A 250-volt 60 Hz, AC only, 20A fused and
propedy grounded electrical supply is required.
A time delay fuse or time delay circuit breaker
is recommended. Use a dedicated circuit,
serving onlythis appliance.
DO NOT USE AN EXTENSION CORD.
RECOMMENDED GROUNDING METHOD
For your personalsafety, this appliance must
be grounded. This appliance has a power
supply cord with a 3-prong grounding plug.To
minimize possible shock hazard, the cord must
be plugged into a mating groundingtype wall
receptacleand grounded in accordance with
the National Electrical Cede (ANSI/NFPA 70)
latest edition and all local cedes and
ordinances. If a mating wall receptacle is not
available, it is the personal responsibilityand
obligation of the customerto have a properly
grounded 3-prong wall receptacle installedby a
qualified electrician.
115V-
230V~
!
Power cord may includea currentinterrupter
device.A testand resetbutton is provided on the
plugcase.Thedeviceshouldbe testedon a
pedodic basisbyfirst pressingthe TEST button
andthenthe RESETbutton.If the TESTbutton
doesnottripor if the RESETbuttonwillnotstay
engaged,discontinue u se ofthe air conditioner and
contact a qualified servicetechnician.
NOTE: The shapemaybe different a ccording to itsmodel.
Use Wall Receptacle
Power Supply
©
@
©
Standard 125V,
3-wire grounding
receptaclerated
15A, 125V AC
Standa_250V,
3-wiregrounding
rece_acle mud
15A,25OVAC
Use 15 AMP. time
delay fuse or 15 AMP.
circuit breaker.
Standard 250V,
3-wire grounding
Use 20 AMP, time
receDtacle rated
delay fuse or 20 AMP.
20A, 250V AC
circuit breaker.
AWARNING
Electrical S hockHazard
Plugintoa grounded 3 prongoutlet.
Donot removegroundprong.
Donot usean adapter.
Donot usean extension c ord.
Failureto followtheseinstructions can resultin
death,fire, or electdcal s hock.
-4-