Before installation, record the model number
listed inside the fixture. Attach receipt in case
of possible warranty issues.
Model number:
requireMents
• The light control requires 120 volts AC.
• If you want to use Manual Mode, the control must
be wired through a switch.
• some electrical codes require installation by
a qualified electrician.
OPeratiOn
Mode:
On-Time
test
5 Seconds
auto
1, 5, or 10 Min
Manual
To Dawn*
accent
Off, 3, 6 Hr,
to Dawn
* resets to Auto Mode at dawn.
Note: When first turned on wait about 1
for the circuitry to calibrate.
Set the ON-TIME switch
on the sensor to TEST.
autO
Set ON-TIME switch to
1, 5, or 10 minutes.
Works: Day Night
x
/
minutes
1
2
test
ON-TIME
test 1 5 10 MIN
ON-TIME
TEST 1 5 10 Min
Manual mode only works at
night because daylight returns
the sensor to AUTO.
Flip the light switch off for
one second then back on to
toggle between AUTO and
MANUAL MODE.
Manual mode works only with
the ON-TIME switch in the 1,
5, or 10 position.
x
MOde switching suMMary
x
x
TEST
x
AUTO
MANUAL MODE
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
D
B
ual
Light comes on half bright for selected time after
dusk (Off, 3 hr., 6 hr., until dawn). Selecting OFF
disables this feature. The motion sensing features
will continue to work as described in this manual.
If motion is sensed, the light turns on full bright for
the ON-TIME (1, 5, or 10 minutes) then returns
to dim mode.
2
ManuaL MOde
ON-TIME Switch at 1, 5, or
10 minutes
Flip light switch off
for one second then
back on*
diMMer cOntrOL
®
rite
1 Second OFF
then...
... back on.