The module may be used to operate a shutters or
curtain motor.
Electrical specifications
• Bus powered: 2.5 CU
• Bus terminal configurable by means of dip-switch:
TERM
• Relay output:
- 230 V~ / 4 A on inductive load
- Use of high inrush current (80 A)
• 3 terminals for 2 buttons for local operation of the
motor (up, down), useful for operating the shutters
or curtain in the immediate proximity
Logical features
• Configurable with IPerSet software, via USB (see
1071/56)
• 254 possible logical addresses
• 3 times: opening/closing time, winding time,
packing time.
• Operation of each shutters for max. 25 events
(sensors or buttons)
• Actions:
- Nine standard Actions: up, down, up always,
down always for controlling sets of shutters and
(*)
Max distance: 70 m
6
possibility of adding delays for offsetting drives
and eliminating consumption peaks, up/down
allowing to use only one control button, go to
position etc.
- Three
additional
standard actions. Eleven Actions for selecting
the operating mode. The operating mode can be
programmed
according
weekdays/weekends).
- 15
cut-out
Actions
activation, close upon action).
- 10 Actions, including 'override down' and
'override up'.
(*)
- Five block Actions, in case of emergency.
.
- Two pairs of timed actions for opening in the
Morning and closing in the Evening, both
configurable
as
deactivated
using
Possibility of associating each timed pair to one
or two possible different sets to associate other
rolling shutter or timer-thermostat modules to
the same group
- Timed opening at dawn (+/- offset), configurable
as automatic or activated/deactivated using
seven specific actions.
- Timed closing at sunset (+/- offset), configurable
modes,
each
with
nine
to
context
(e.g.
(neutral,
open
upon
automatic
or
activated/
seven
specific
actions.
DS1071-014B