Axis A1601 Guia De Instalacion página 25

Ocultar thumbs Ver también para A1601:
Tabla de contenido
6–pin terminal block
Function
Pin
1
DC ground
2
DC output
3–
Configurable
6
(Input or
Output)
1
DC ground
2
DC output 12 V
3
I/O configured as input
4
I/O configured as output
AXIS A1601 Network Door Controller
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Digital input – Connect to pin 1 to activate, or
leave floating (unconnected) to deactivate.
Digital output – Internally connected to pin 1 (DC
ground) when active, and floating (unconnected)
when inactive. If used with an inductive load,
e.g., a relay, connect a diode in parallel with the
load, to protect against voltage transients. Each
I/O is capable of driving 12 V DC, 50 mA (max)
external load, if internal 12 V DC output (pin 2) is
used. In the case of using open drain connections
in combination with an external power supply,
then the I/Os can manage DC supply of 0–30 V
DC, 100 mA.
25
Specifications
0 V DC
12 V DC
Max load = 50 mA for
each I/O
0 to max 30 V DC
0 to max 30 V DC,
open drain, 100 mA
Tabla de contenido
loading

Tabla de contenido