AXIS A1601 Network Door Controller
Configurable (Input or
Output)
Important
• When the reader is powered by the controller, the qualified cable length is up to 30 m
(98.4 ft).
• When the reader is not powered by the controller, the qualified cable length for reader
data is up to 150 m (500 ft) if the following cable requirement is met: AWG 22.
Supervised inputs
To use supervised inputs, install end of line resistors according to the diagram below.
UL: Supervised inputs were not evaluated by UL for burglary use. Only door monitor and REX
support supervision with end of line resistors.
7–8
i
Input
ii
0 V DC (-)
Digital input —
Connect to pin
1 to activate,
or leave floating
(unconnected) to
deactivate.
Digital output —
If used with an
inductive load, e.g.,
a relay, connect a
diode in parallel with
the load, to protect
against voltage
transients.
22
0 to max 30 V DC
0 to max 30 V DC,
open drain, 100 mA