Technical specifications

Visible laser diode
Laser class
Work area (Ø) *
Precision *
Self-levelling range
Power supply
Operating duration
– 1 beam (continuous
operation)
– 2 beams (continuous
operation)
Temperature range
– for operation
– for storage
Weight (with batteries)
*
When used with a laser detector (optional).
Instructions for use
The most important operating steps are
ALC 2/1
explained at the end of these instructions
on the illustrated pages.
630–650 nm
See from page 144.
2
The laser detector LR 1 can be used to expand
the application options.
30 m
Checking precision
< 3 mm/10 m
± 6 °C
It is recommended to check the device regularly
to ensure that it is always precise.
3 x LR6/AA
If the precision deviates from the permitted
tolerance range, the device must be taken
to a customer service workshop authorised
≤ 25 h
by the manufacturer.
Have the device adjusted by authorised
≤ 12.5 h
technicians only.
The steps required to check the precision
are explained at the end of these instructions
–18 °C–50 °C
on the illustrated pages.
–40 °C–70 °C
See from page 150.
0.28 kg