- Bind the adhesive tape supplied
around the outlet (6).
Wall Model
- Drill a 115mm diameter hole in the
chosen position through the wall.
Slope the wall sleeve downwards to
prevent rainwater running through
the duct into the unit. The end with
the larger diameter should be on the
room side.
- Loosen the screw (4), which holds the
grille in place (1) and remove grille.
- Mark the 4 screw hole positions.
Drill, plug and screw into position.
Repeat this process for the external
grille sub-frame. Fix the exterior grille
in position, whilst ensuring that the
louvres are positioned downwards.
- Check that the wall tube is not
distorted and that the impeller turns
freely.
- This fan must be installed by a
competent person. Complete electrical
wiring of fan as outlined in the Wiring
Instructions below. Then refi t the grille
and tighten the screw (2).
- Bind the adhesive tape supplied
around the outlet (6).
Window Model (Fig. 5)
These models have been designed
for installation on a window (single or
double glazed) using the EDM-100
Window Fixing Kit.
Fig.5
1 & 10 – Protection grille
2 – Cable entry point
3 – Connection cover
4 – Fixing screw
5 – Connection terminals
6 – Outlet
7 – Rubber joints
8 – Spacers
9 – Threaded ring
- Cut a 105mm -diameter hole in glass.
- Loosen the screws on the front and
back protections grilles (1 and 10).
- Loosen the threaded ring (9) and
remove the 4 spacers (8).
- Mount the fan depending on the
installation requirements so that the glass
is between the two rubber joints (7):
Fig. 5a: All the spacers on the outside
Fig. 5b: All the spacers on the inside
Fig. 5c: Spacers on the outside and
the inside.
- For double-glazing, one or more
spacers may be discarded.
- Fix the threaded ring. Fix the exterior
grille in position, using the screws
provided.
This fan must be installed by a
competent person. Complete electrical
wiring of fan as outlined in the Wiring
Instructions overleaf. Then refi t the front
grille and tighten the screw (2).
WIRING INSTRUCTIONS
IMPORTANT: ENSURE THAT THE MAINS
SUPPLY IS SWITCHED OFF BEFORE
MAKING ELECTRICAL CONNECTIONS.
The EDM-100 12V is suitable for
connection to 12V 50Hz AC electrical
supply from a CT-12/14 or CT-12/14H
transformer. It is Safety Extra Low
Voltage and must not be earthed.
There are two options for cable entry
to the fan. If using recessed wiring, the
cable must be introduced through the
slot (7) (Fig. 1). If using surface wiring
the cable must be introduced as shown
in Fig 3 and the break-out region on the
left hand side of the front grille should
be removed.
For access to the fan terminals, remove
the safety cover screws and hinge up
(Fig. 4).