5.3
Filter Cleaning
In order to guarantee maximum suction performance, the unit is equipped with an automatic cleaning
function for the filter unit.
EN
The cleaning process is carried out:
• When the suction performance is insufficient (when the flow velocity falls below a specified level);
• When the unit is switched on;
• Before the dust drawer is removed, when the cleaning function is activated (see chapter 6�2 Empty dust
drawer)�
If the flow velocity falls below the specified level for more than 1 minutes, the suction is interrupted and
the cleaning function is activated:
⇒ Flow velocity below specified level.
♦ The suction turbine is stopped�
♦ The cleaning function is carried out� The cleaning function takes approx� 8 seconds and is indicated
by an acoustic signal�
♦ The suction turbine is re-started�
6
Cleaning / Maintenance
Opening the device, other than for the processes described below, is not permissible!
6.1
Cleaning
Use a damp cloth to clean the outside of the unit�
Do not use abrasive or solvent-based cleaning agents�
6.2
Empty Dust Drawer
After the set time period has expired (see chapter 6�2�1), a signal to empty the dust
drawer will occur�
Before the dust drawer is emptied, a filter cleaning function is carried out so that loose
dust particles fall into the dust drawer�
The time period has expired:
♦ An acoustic signal will occur 3 times�
♦ The display dust drawer (24) lights up�
When the suction has stopped, an acoustic signal occurs 3 times and a filter cleaning
function is carried out�
When the filter cleaning function has finished:
⇒ Pull the dust drawer (3, Fig� 1) out to the front and empty�
⇒ Replace the dust drawer until it clicks into place�
⇒ Press the enter key (25) (the counter which determines the time period is re-set)�
♦ An acoustic signal confirms the input.
♦ The display dust drawer (24) light disappears�
If the dust drawer is not emptied, the display for the dust drawer will remain alight (24, Fig. 8).
When the unit is switched off/on an acoustic signal will occur to remind that the dust drawer
needs emptying.
- 10 -
24
25