Changing the diverter cartridge (figures 3, 4, 6, 7)
– Remove the shelves (22) and the cover flanges(20) undo the locking screw(19) of the shower bar
and the sleeve(18) and detach the shower bar.
– Undo the locking screw(14) of the battery casing(15), detach the casing and disconnect the wire(21).
– Close the water inlet to the faucet.
– Undo the locking screws (11) of the faucet body and detach the body by pulling it off firmly.
– Open the couplings(24) of the copper pipes coming from the diverter.
– Disconnect the connectors(C, D) from the printed circuit board.
Connectors: A=Membrane switch, B=Electronic box, C=Stepper motor, D=Printed circuit board of
diverter
– Detach the diverter body from the thermostat body by unscrewing the nut(26).
– Detach the motor gear(27), diverter circuit board(28), limiter(29) part and the locking nut(30) from
the diverter body.
– Detach the diverter cartridge(31) e.g. by prying it off with two screwdrivers.
– Install the diverter cartridge. Note! Do not press at the end of the stem.
– Reassemble in reverse order.
Changing the motor/gear (figures 3, 4, 6, 7)
– Remove the shelves (22) and the cover flanges (20) undo the locking screw (19) of the shower bar
and the sleeve (18) and detach the shower bar.
– Undo the locking screw (14) of the battery casing (15), detach the casing and disconnect the wire (21).
– Close the water inlet to the faucet.
– Undo the locking screws (11) of the faucet body and detach the body by pulling it off firmly.
– Open the couplings (24) of the copper pipes coming from the diverter.
– Disconnect the connectors (C, D) from the printed circuit board.
– Detach the diverter body from the thermostat body by unscrewing the nut (26).
– Detach the motor gear (27) from the diverter body.
– Install the new motor/gear.
– Reassemble in reverse order.
Troubleshooting
The flow-rate from the faucet has
diminished over time
The text "E10" on the display
The text "E20" on the display
The text "E30" on the display
No water from shower
(on display text E11)
No water from shower and
temperature on display
The shower is closed and
the little flow from hand- or head shower
– Filter/non-return valve is blocked
– Alert for low battery voltage. Change the
batteries
– The connector to the diverter printed circuit
board is open or there is some fault in the
diverter board.
– The membrane switch is broken. Change the
membrane switch
– Batteries are dead.
– Faulty diverter
– Faulty diverter