Adjustable Parameters - Oras Ventura 8065 Manual De Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 22

Adjustable parameters:

1. Default flow-rate, 80%
2. Automatic switching from handshower to upper shower, off
3. Automatic switching temperature for the handshower, 38°C
4. Automatic switching temperature from upper shower to handshower, 44°C
5. Maximum flow period, 5 min.
6. Temperature read-out option, C
7. Follow-up of which shower used/flow-rate of previous use, 3 min.
8. Audio signal for on/off button, on
9. Factory default for shower, off
Installation (figures 2, 3 and 4)
– Place the eccentric unions so that they protrude 40±5 mm from the wall and the cutoff valves are
to downwards.
– Position the nuts (11) and fastening sleeves (9) with their washers (8) over the eccentric unions (7).
– Use the mounting plate (10) and a bubble level to ensure that the distance between the eccentric
unions is 150 mm and that they are at the same height.
– Measure the position for the upper hanger (13). Drill the installation hole in the wall.
– Attach the upper hanger (13) and its washer (12).
– Detach the battery casing(15) from the faucet bodyby opening screw (14).
– Push the faucet body over the eccentric unions and tighten the nuts (11).
– Fit the shower bar's groove to the upper hanger's (13) groove from the side of the panel and press
the shower bar to the sleeve (17) on the panel.
– Tighten the sleeve (18) on the upper hanger (13). Do up the locking screw (19) of the shower bar.
Attach the cover flanges (20) to the shower bar.
– Insert the batteries to their casing. When needed, insert the casing's washer. Connect the battery
casing (21) to its counterpart.
– Open the water inlet to the faucet and check that the joints are tight.
– Fasten the battery casing (15) with a screw (14).
– Install the handshower and its hose.
– Attach the shelves (22) behind the shower bar through the groove below the upper hanger (13).
Temperature adjustment (figure 5)
– Grab the temperature adjustment knob(6) firmly and pull it off.
– Switch the shower on.
– Use the adjustment knob(6) to adjust the water temperature as required.
– Place the temperature adjustment knob(6) back over the stem, aligning the limiter button with the
shoulder.
– Push the temperature adjustment knob(6) firmly back in place.
Cleaning the litter filters (figures 4, 6)
– Undo the locking screw (14) at the bottom of the battery casing.
– Detach the battery casing (15) and open connector (21).
– Close the water inlet to the faucet.
– Unscrew the filter/one-way valves (23) in the thermostat body and clean them under running water.
– Reassemble in reverse order.
15
(range 30-100%)
(on/off)
(30-40°C)
(40-45°C)
(1-30 min.)
(C/F)
(1-5 min.)
(on/off)
(on/off)
Tabla de contenido
loading

Tabla de contenido