Troubleshooting And Repair; Technical Data - Husqvarna S 11 Instrucciones Para El Manejo

Ocultar thumbs Ver también para S 11:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 89
14

Troubleshooting and repair

Malfunctions cannot always be traced back to defects in the vacuum cleaner.
Fault
Suction power drops
Vacuum cleaner does not start
The vacuum cleaner does not start
when the tool is switched on in the >A<
or >RA< mode
PE emptying and disposal bag is sucked
against the filter
Vacuum cleaner with dust classes M
or H: with inserted filter bag, dust is
accumulating in the container
Do not try anything else, contact customer services.
15

Technical Data

Typ: IS
Voltage
Frequency
Rated power
Max. power
Air flow*
Negative pressure*
Air flow**
Negative pressure**
Noise level
Weight
Dimensions (l x w x h)
* at the fan
** at the hose
14 - en
Cause
Filter dirty
Filter bag full
Container full
Motor protection filter blocked
Nozzle, tube or hose blocked
Mains plug not in socket
No mains voltage
Mains connection cable defective
Cover not properly closed
Water sensor switched off
Vacuum cleaner in standby mode >A<
or >RA<
Electrical tool not plugged into socket
on the vacuum cleaner
Solenoid valve of pneumatic on-off
unit*contaminated
Incorrect position of rotary slide
Incorrect position of rotary slide
ISC L/M/H-1425
(ISC L/M/H-1450)
V
220-240
Hz
50/60
W
1200
W
1400
l/s (m³/h)
73 (263)
hPa/MG
270
l/s (m³/h)
42 (151)
hPa/SE
235
dB(A)
69
kg
12,1 / 17,1
45 x 39 x 49 / 59,5 x
cm
46,5 x 96
NOTE
Remedy
Clean
Change
Empty
Clean
Clean
Plug mains plug into socket
Check fuse
Replace
Close
Empty container
Set switch to >I< (see „3 Display and control
elements" on page 9)
Plug mains plug into socket on the vacuum cleaner
Rinse with alcohol
Set rotary slide to position OPEN ▲(see „7.4 Insert
PE emptying and disposal bag*" on page 12)
Set rotary slide to position CLOSE ▲(see „7.3
Insert fleece filter bag" on page 12)
* depending on model
Tabla de contenido
loading

Tabla de contenido