Operating Instructions
FGS
4
Mounting
ACHTUNG
WARNING
8 007 716/KA 06/31-03-00
Mounting
The relevant (poss. country-specific) regulations must be
observed when installing the FGS.
The FGS may only be used for suitable machinery. The device
must be mounted such that the following actions are not
possible (Fig. 2):
Reaching around the safety curtain
Reaching over the safety curtain
Reaching under the safety curtain
Standing behind the safety curtain
The sender and receiver are mounted using rigid or pivoted
mounting brackets (Fig. 4). The sender and receiver (together
with any additional modules) are attached to the brackets
using sliding nuts in the profiles. The device must be
positioned as shown in the dimensional drawing (Fig. 5) (Host
sensor, Guest sensor).
The dimensions are in millimetres (mm).
Warning
To prevent the FGS – and consequently the protective field –
from shifting when using sliding nuts, it is essential to observe
dimensions C and D in the dimensional drawing when secured
(fig. 5 in the appendix):
The sender and receiver must be installed in the same
direction. Installation with a 180° scrived is not permitted.
© SICK AG • Safety Systems • Germany • All rights reserved
GB
Chapter 4
133