Expansion modules
Connection options
Primary lines PL 1 - PL 6
Connection options
Terminal resistance in kΩ
Interruption voltage in V
Maxiumum line resistance in Ω 100
Alarm threshold
Maximum response time in ms 200
Control outputs S1 - S3
Principle
Maximum voltage in V
Maximum over threshold
voltage in V
Maximum current in mA
Control output S4
Principle
Minimum over threshold
voltage in V
Minimum over threshold
voltage in V
Maximum current in mA
Bosch Security Systems B.V.
Technical data | en
6 detector zones can be
programmed as holdup,
intrusion, tamper or bolt
–
12k1 for ISP-EMIL-120
and ISP-PCBA-EMIL
–
4k7 for ISP-EMIL-3RDP
6
± 40% of terminal resistance
Open collector, active 12 V, 0
V switching
30
1.4
20
12 V switching
11.88
13.13
100, refer to Output current
dependencies
2020-04 | 08 | F.01U.076.548
41