Emotron VSC 48-009 Serie Guia De Inicio Rapido página 63

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

2- Manual/Automatic Restart Modes
Function
Description
Code no.
Momentary Power
2-00
Loss and Restart
Momentary Power
2-01
Loss Ride-Thru Time
(Seconds)
Auto Restart Delay
2-02
Time (Seconds)
Number of Auto
2-03
Restart Attempts
Auto Restart
2-04
Method
Direct Running After
2-05
Power Up
2-06
Delay-ON Timer (s)
2-07
Reset Mode Setting
Kinetic Energy
2-08
Back-up
Deceleration Time
62
Software index
Range/Code
0000: Momentary power loss
and restart disable
0001: Momentary power loss
and restart enable
0002: Momentary power loss
and restart enable while CPU is
operating. (According to the
capacity of DC power)
0.0 to 2.0
0.0 to 800.0
0 to 10
0000: Enable Speed Search
0001: Normal Start
0000: Enable Direct running
after power up
0001: Disable Direct running
after power up
0.0 to 300.0
0000: Enable Reset only when
Run command is Off
0001: Enable Reset when Run
command is On or Off
0.0: Disable
0.1 to 25.0: KEB Deceleration
Time
Factory
setting
0000
0.5
0.0
0
0000
0001
0.0
0000
0.0
Emotron AB 01-3990-11r3
Re-
marks
*8
Tabla de contenido
loading

Este manual también es adecuado para:

Vsc 48-013 serieVsc 48 018 serie

Tabla de contenido