NOTE:
Use V/F Control Mode if:
(1) You want one VSD to drive several motors simultaneously
(2) The motor's nameplate is unknown or the motor specifications are too
specialised, this will cause autotuning fault.
(3) The specification of VSD and motor differ by more than 1 class.
One VSD drives several motors (only V/F mode available), set the motor
parameter to comply with the following rules:
(1). As for the current, total up the rated current of all motors.
(2). As for others, input correct VF pattern parameter (10-4 to 10-9).
When the nameplate of the motor is unknown, the VSD will set the internal
parameter as if for a standard motor.
When parameter 0-00 is set to 2, the keypad will display 'Err2' when
performing autotuning.
When using Vector control, set to 0-01 to 0-05 for max. and min. values with
a standard motor specification limit (one level less and one level more).
When using V/F Control, no range to be set.
VSC programmable functions list
Parameter group no.
0-
1-
2-
3-
4-
5-
6-
7-
8-
9-
10-
11-
12-
13-
14-
Emotron AB 01-3990-11r3
Drive Operation Mode
Start/Stop and Frequency Control Modes
Manual/Automatic Restart Modes
Operating Parameters
Digital Display Operation Mode
Multifunction Input Terminals (MFIT)
Jog, and Preset (MFIT) Speed Setting on Keypad
Analogue Input Signal Operation
Multifunction Output Relays and Output Signal Operation
Drive and Load Protection Modes
Volts/Hz Pattern Operation Mode
PID Operation Mode
PID "Limits" and "Out of Range" Mode
Communication Mode
Motor Autotuning Parameters
Description
Software index
59