Würth 0715 53 790 Traducción Del Manual De Instrucciones De Servicio Original página 15

Medidor de espesor de revestimiento de pintura
Ocultar thumbs Ver también para 0715 53 790:
Tabla de contenido
If the displayed measured value on the reference plate or the substrate is outside
the measurement accuracy, carry out a zero adjustment as follows:
Place the probe on the reference plate or substrate
Press the button on the appliance briefly.
Raise the appliance by at least 10 cm.
A control number appears on the display.
3
A signal tone is audible.
3
Zero adjustment is completed.
3
Dirt or roughness can cause measurement fluctuations.
Place the measuring head flush on the surface to be measured.
In order to avoid tilting, hold the device at the handles near the measuring
head.
The measured value appears on the display.
3
A signal tone is audible.
3
At the same time, information is displayed as to which probe the appliance
3
has used for measurement. This is particularly important when using the dual
probe.
If zero adjustment is performed on a non-metallic substrate or if the appliance
3
is used incorrectly, "Zero Reference Error" is displayed.
Measurements outside the probe measuring range result in "INFI"
3
(infinite) being displayed.
The appliance switches on automatically when the probe is placed on the
3
substrate and switches off again after approx. 30 seconds when not in use.
For measurements on bars, tubes, etc., use the V groove in the measuring head.
Do not carry out measurements on magnetised parts.
Magnetic fields can influence the measurement result in the Fe part.
Strong electromagnetic fields can influence the NFe measurement.
Operation
15
Tabla de contenido
loading

Tabla de contenido