18
TROUBLESHOOTING
- CAUTION!!! All maintenance operations must be
performed exclusively with the machine stopped off and
the power plug disconnected from the mains.
Problem
Voltage not reaching
supply line
Electrical socket and
plug are not properly
connected
The power cable from
the plug to the panel is
An electrical wire in the
Motor fails to start
motor terminal board is
when switch is
disconnected
operated
An electrical wire in the
electrical panel is
disconnected
The ON switch is faulty
The thermal safety
device has been
triggered
Carriage does not
Dirty runners
slide horizontally
easily
No cooling water
Refer to "cleaning and maintenance of the
reaching disc
The disc is worn
Disc fails to cut
* Operation to be carried out by an electrician
Tools supplied
• double-ended wrench CH 10-13
• open ended wrench CH 36
IMER INTERNATIONAL S.p.A
Causes
Corrective action
Check the line *
Restore correct
connection
Change the cable *
cut off
Restore the
connection *
Restore the
connection *
Replace the switch *
Wait a few minutes
and try again
Clean the runners
cooling system" (par. 17.5)
Replace with new
disc
19
DISPOSAL
The saw must be disposed in accordance with current
regulations.
The barred bin symbol on the equipment
indicates that, at the end of its service life,
the product must be scrapped separately
from other materials.
The manufacturer is responsible for separate scrapping of the
equipment at the end of its service life. The user must
therefore contact the manufacturer and follow the instructions
given by the latter for separate scrapping of the equipment at
the end of its service life.
Separate scrapping for subsequent recycling, treatment and
eco-compatible disposal contributes to avoiding negative
effects for the environment and for the health of persons, and
promotes the reuse/recycling of the materials of which the
equipment is fabricated.
Incorrect/illegal scrapping is punishable by law.