3. Indications of compromised safety
If there is any doubt about save operation being certain,
the unit must be disconnected from the power supply
and secured against accidental operation. Operation may
no longer be safe if, for instance, the apparatus is visibly
damaged or no longer works correctly. The apparatus is
only completely disconnected from the power supply if
the power cord has been pulled out of the plug-in socket.
4. Disinfection and sterilization
Contaminated surfaces of the apparatus, light probe and
anti-glare cone must be disinfected or autoclaved before
each use.
5. Light output
Before each use, make sure that the light output permits
adequate curing. For this purpose, check the light probe
for contamination and use the cleaned light meter to test
the light output if necessary.
6. Heat development
As it is the case with all high-performance lights, the
high light output results in a certain development of
heat. Prolonged exposure of the pulp and soft tissues
may result in damage. Therefore, the corresponding
curing recommendations as regards the program and
curing time have to be observed. In addition, uninterrupted
curing times of more than 40 seconds in the same area,
as well as direct contact with the gingiva, oral mucous
membrane or skin have to be prevented. Prevent heat
accumulation when polymerizing with a rubber dam in
place.
7. Eye protection
Direct or indirect exposure of the eyes must be prevented.
Prolonged exposure to the light is unpleasant for the
eyes and may result in injury. It is therefore advisable to
use the anti-glare cones provided. Individuals who are
generally sensitive to light, who take photosensitizing
drugs, or who have undergone eye surgery and people
who work with the apparatus or in its vicinity for long
periods of time should not be exposed to the light of this
device and wear protective goggles that absorb light
below 500 nm.
8. Maintenance and cleaning
Any repair work must only be performed by a certified
Ivoclar Vivadent Service Center. Liquids or any foreign
substances must not enter the handpiece, handpiece hol-
der and particularly the power pack during cleaning
(electrical shock hazard).

Start-up

9. Disposal
Do not dispose of the apparatus with normal domestic
waste. Dispose of curing lights and batteries according to
the corresponding national rules and regulations.
Check the delivery for completeness and any possible
transportation damage (see Delivery form). If components
are missing or damaged, immediately contact your dealer
or local Service Center.

Handpiece holder

Open the battery compartment, which is located on the
underside of the handpiece holder. Insert the batteries
supplied with the kit according to the polarity indicated
and then close the compartment. Place the handpiece
holder on a suitable flat surface. The handpiece holder
switches on automatically when the light meter is
activated by blue light (see Measuring the light output).

Handpiece

Before you switch on the unit, make sure that the local
power supply complies with the power supply indicated
on the rating plate. The rating plate is attached to the
underside of the power pack.
After that, connect the power pack to the power supply.
Before you insert the light probe, remove the protective
foil on the corresponding opening of the handpiece.
Slightly rotate the light probe while attaching it to the
handpiece. After that, mount the anti-glare cone on the
light probe.