Tabla de contenido
  • English

  • Deutsch

  • Français

  • Italiano

    • Português

    • Svenska

    • Dansk

      • Suomi

      • Dutch

      • Ελληνικά

        Idiomas disponibles
        • ES

        Idiomas disponibles

        • ESPAÑOL, página 7

        Enlaces rápidos

        CRT
        CRT
        buffer
        buffer
        ®
        ®
        Instructions for Use
        Gebrauchsinformation
        Mode d'emploi
        Istruzioni d'uso
        Instrucciones de uso
        Instruções de Uso
        – For determining the buffer capacity of saliva
        – Zur Bestimmung der Pufferkapazität des Speichels
        – Pour la détermination du pouvoir tampon de la salive
        – Per la determinazione del potere tampone della saliva
        – Para la determinación de la capacidad buffer de la saliva
        – Para determinar a capacidade buffer da saliva
        – För bedömning av salivens buffertkapacitet
        – Til bestemmelse af bufferkapaciteten i saliva
        – Syljen puskurikapasiteetin määrittelyyn
        – Voor het bepalen van de buffer capaciteit in het speeksel
        – Για τον προσδιορισμ της ρυθμιστικής ικαν τητας
        του σάλιου
        For dental use only!
        Caution: U.S. Federal Law restricts this device to sale
        by or on the order of a licensed dentist.
        Made in Liechtenstein
        Ivoclar Vivadent AG, FL-9494 Schaan/Liechtenstein
        553517/0503/5/WE3/G
        Bruksanvisning
        Brugsanvisning
        Käyttöohjeet
        Bruksanvisning
        Productinformatie
        Oδηγίες Xρήσεως
        English
        Instructions for Use
        Description
        CRT buffer is used to determine the buffer capacity
        of saliva by means of a test strip featuring a special
        indicator system.
        Indication
        – In vitro diagnostics
        – Determination of the buffer capacity of saliva
        Application
        The test is professionally conducted by the dentist
        or skilled personnel.
        Note:
        For at least one hour before the test is conducted,
        patients should
        – neither eat nor drink anything,
        – not chew any chewing gums,
        – not smoke,
        – not brush their teeth,
        – not use any mouthwashes.
        Step-by-step procedure
        1. Have your patient sit upright in a relaxed
        position.
        2. Stimulate salivation by having your patient chew
        a paraffin pellet.
        3. Collect the saliva in a calibrated container.
        Tip: Collect the saliva over a defined period of
        5 minutes and determine the salivation rate
        (ml saliva/min) at the same time.
        Findings for adults:
        Normal: ≥ 1 ml saliva/min.
        Too low: < 0.7 ml saliva/min.
        Tabla de contenido
        loading

        Resumen de contenidos para Ivoclar Vivadent CRT buffer

        • Página 7 Instrucciones de Uso Ad esclusivo uso odontoiatrico! Descripción: Data di stesura delle istruzioni d´uso CRT buffer sirve para la determinación de la 05/2003 capacidad de amortiguación de la saliva, y está dotado con un sistema de indicadores especial. Ivoclar Vivadent AG...
        • Página 8: Eliminación

          ≥ 1 ml saliva/minuto – No utilizar una vez caducado demasiado bajo < 0,7 ml saliva/minuto. 4. Extraer la tira de prueba CRT buffer del envase Mantener fuera del alcance de los niños sin tocar el campo activo amarillo.
        • Página 18 Fax +423 235 33 60 Fax +33 450 68 91 52 Fax +64 9 914 9990 www.ivoclarvivadent.com Ivoclar Vivadent GmbH Ivoclar Vivadent Polska Sp. z.o.o. Ivoclar Vivadent Pty. Ltd. Dr. Adolf-Schneider-Str. 2 ul. Jana Pawla II 78 1 – 5 Overseas Drive...

        Tabla de contenido