Important Remarks - Sammic ES-100 Manual De Instrucciones

Ocultar thumbs Ver también para ES-100:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
MODELS
This manual describes the installation, oper-
ation and maintenance of vegetable drainage
machines ES-100 and ES-200. The model ref-
erence number and its features are specified on
the name plate attached to the machine.
Machinery Directive 2006/42/EC.
Low Voltage Directive 2006/95/EC.
Electromagnetic
Compatibility
2004/108/EC.
Vegetable drainage standard: UNE-EN 13621
Hygiene and food contact materials standard:
ANSI-NSF 8 and ANSI-NSF 51.
Protection level in accordance with standard
UNE-EN 60529: Controls IP-55 and rest of
machine IP-23
The 120V/60Hz/1~ models comply with the
regulations UL-763 and CSA C22.2

IMPORTANT REMARKS

- Before using the machine for the
first time, clean the basket with
(lukewarm) soapy water, rinse
and leave to dry. Use a damp
cloth to clean the rest of the
machine.
- This machine this not designed for
use by people (including children
aged 8 and above) with reduced
physical, sensory or mental capa-
bilities or lacking the necessary
experience or knowledge, unless
they have received supervision
or instructions from a health and
safety expert and they under-
stand the risks of the appliance.
Children should not play with the
appliance.
The cleaning and maintenance to
be performed by the user should
not be made by unsupervised
children.
- This machine must monitored and
must not be left running unsuper-
vised.
- The models cited in the manual
have been designed for use in
hotels, restaurants, catering and
commercial applications.
- The manufacturer is not respon-
sible when the product is used
incorrectly or differently than the
use mentioned above. Such as,
sanitary use, chemical use, use in
explosive atmospheres, etc.
- Machine noise level, while run-
ning, at a height of 1.6 m and
a distance of 1 m, less than 70
dB(A). Background noise: 32
dB(A).
- If the power cable is damaged
and a new one must be installed,
only a SAMMIC authorised tech-
nical service can replace it.
EN
6
STARTING UP AND INSTALLATION
For optimum performance and long-lasting pres-
ervation of your machine, carefully follow the
installation instructions given in this manual.
Location
The drainage machines are fitted with wheels
for mobility and the machine's location therefore
requires:
Directive
a) A flat, horizontal and rigid surface to prevent
vibrations and noise. It is essential to install
the drainage machine in accordance with
the diagram and lock the three wheels.
b) Water drainage outlet. Minimum diameter 35
mm (1 3/8 in). When connecting the drainage
avoid bends and slopes.
If you do not have the drainage machine, you
can fit a container with a maximum height of
150 mm (6 inches) just below the machine's
overflow unit. Take into account that it must be
emptied after several cycles.
Check that the machine's drainage pipe is not
blocked.
c) Electricity mains outlet.
Once the installation task has been completed
if you wish to store the machine under a count-
er adhere to a minimum storage height of 700
mm (27.6 inches) for the ES-100 and 830 mm
(32.7 inches) for the ES-200.
Electric connection
Check that the machine's electrical characteris-
tics match the mains power supply.
The drainage machine is supplied for 230V 50-60
Hz single phase power or 120V 50-60 Hz single
phase power.
Prepare a wall-mounted socket with a general
cut-out switch, residual current protection and a
2P (from 13A to 20A) circuit breaker, with its cor-
responding plug. Fit a general switch or the plug
in an accessible place to disconnect the machine.
WARNING: THE GROUNDING CONNECTION
IS
COMPULSORY.
ELECTROCUTION. The converter includes a
filter that shunts power disturbances to grounding
safety. Therefore, the residual current device
may cause untimely tripping. You are advised
to use a suitable residual current device for the
machine or a super immunised RCD.Moreover,
the machine includes an external screw for its
connection to a ground equipotential system.
The motor is three-phase in every model and con-
trolled by a variable frequency drive.
Rotation direction: the basket must rotate in accor-
dance with the arrow shown on the machine
(counter clockwise). If it rotates in the opposite
direction, the rotation direction is inverted by
releasing the cover of the control box and inter-
changing 2 wires of the motor's cabling, in the
variator output.
Power cable characteristics
The drainage machines come with a 1.5 m ther-
moplastic-sheathed power cable. The power plug
must always be accessible to the user.
FUNCTIONS OF THE ELECTRONICS CON-
TROL Diag. A
cycle from among three different time spans: The
pilot lights indicate the selected cycle.
"a": Short cycle.
"b": Intermediate cycle.
"c": Long cycle.
With the cover closed and without selecting auto-
matic mode, pressing this key starts the cycle and
the corresponding pilot light "d" is lit.
At the end of cycle the machine automatically
stops and beeps. The cycle can also be stopped
manually by pressing this key once again. In all
these cases the "d" pilot light switches off.
Selecting automatic mode:
With the cover open, if you press this button the
"d" pilot light related to this button starts to blink,
indicating that the "automatic" function has been
activated. In automatic mode, if the cover is
closed, the cycle starts automatically without the
need to press any buttons.
At the end of cycle the machine automatically
stops and beeps. It is also possible to stop the
cycle manually, by pressing the "cycle start-up"
button (Diag.- A 3). In all these cases the "d" pilot
light switches off. When the cover is opened, the
"d" pilot light starts to blink again, indicating that
the "automatic" function is still activated.
To reset this "automatic" function with the cover
open and the "d" pilot light flashing, press the
"cycle start-up" button again (Diag. A-3). The
"automatic" mode is reset and the "d" pilot light
switches off.
DANGER
OF
stops the slow speed and the "f" pilot light switches
off. The machine responds to this button when it
is stopped.
GENERAL SWITCH (1)
CYCLE DURATION SELECTOR
(2)
By successively pressing key "2"
one selects the duration of the
STARTING UP THE CYCLE AND
SELECTING AUTOMATIC MODE
(3):
Starting up the cycle:
LOW-SPEED SELECTOR (4)
Pressing this key starts the slow
speed and the related "f" pilot light
is lit. Pressing this key once again
UNBALANCED LOAD PILOT LIGHT
(Diag.-A e)
The drainage machine is fitted with a
Tabla de contenido
loading

Este manual también es adecuado para:

Es-200

Tabla de contenido