ENGLISH
5
Electrical installation
5.1
Choice of battery
The total battery capacity must be sufficient for the size of the bow
thruster; see the table. See page
The minimum battery capacity is specified in the table; with a lar-
ger battery capacity, the bow thruster will perform even better!
We recommend Vetus maintenance free marine batteries; these can
be supplied in the following sizes: 55 Ah, 70 Ah, 90 Ah, 108 Ah, 120
Ah, 143 Ah, 165 Ah, 200 Ah and 225 Ah.
We also recommend that each bow thruster is powered by its own
separate battery or batteries. This allows the battery bank to be placed
as close as possible to the bow thruster; the main power cables can
then be short thus preventing voltage losses caused by long cables.
Always use batteries whose type and capacity are compatible for
their use.
Be sure to only use 'sealed' batteries if the batteries are located
in the same compartment as the bow thruster.
Vetus 'SMF' and 'AGM' maintenance-free batteries are ideal for
this application. Batteries that are not 'sealed' may produce small
amounts of explosive gas during the charging cycle.
MCVB boosted charge function
Using the MCVB boosted charge function, the 48 Volt motor can be
used in an (existing) 24 V on-board power grid.
By connecting the 24 Volt battery bank to the MCVB boosted char-
ge connection, the 48 Volt, battery bank is charged. An additional
charging facility is not required. See page
diagram.
As a standard, the MCVB boosted charge function is only suitable
for Lead acid batteries
5.2
Main power cables (battery cables)
The minimum diameter and battery capacity must be sufficient for
the bow thruster's current draw in use. Consult the table on page
114
for the correct values.
The maximum operating time and the thrust, as specified by
the technical details in your bow thruster installation and op-
erating manual, are based on the recommended battery ca-
pacities and battery connection cables.
5.3
Main switch
see page
112
The main switch must be fitted to the 'posi-
tive cable' . The Vetus battery switch type
BATSW600 is a suitable switch.
22
020814.01
114
for the applicable battery capacity.
n
ote
113
for the connection
n
ote
n
ote
5.4
Fuses
Main power fuse 1, see page
A fuse must be included in the 'po-
sitive cable' for the main switch, as
close to the battery as possible.
This fuse protects the on-board po-
wer cabling from short circuits.
For all fuses we can suppy a fuse holder, Vetus part no.: ZEHC100.
See page
114
for the size of the fuse to be used.
When replacing the fuse, the replacement must be of the
same rating.
5.5
Connecting the main power cables and config-
uring the bow and/or stern thruster
For connection diagrams, see also page
BOWB300
8 - 10 Nm
(6 - 7 ft-lbf )
48 Volt
Make sure that no other electrical parts come loose when con-
necting the electric cables.
Check all electrical connections after 14 days. Electrical parts
(such as bolts and nuts) may come loose as a result of fluctua-
tions in temperature.
• Apply cable terminals to the battery cables and connect the ca-
bles to the motor controller.
Make sure that the cable terminal on the negative cable cannot
cause a short circuit to the lowest of the three motor connecti-
ons on the controller!
The tightening torque of bolts in the motor regulator is a
maximum of 10 Nm (7 ft-lbf).
vetus® Installation manual BOW PRO Series Thrusters: BOWB285 - BOWB300 - BOWB320
112
n
ote
112
n
ote