V-TAC VT-524-S Instrucciones De Instalación página 3

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 12
4) Drill out the two fixing holes located on the back of the luminaire, hold the luminaire in the required
location and use these holes as a template mark on the location of the fixing holes on the wall/ceiling (Please
note when drilling fixing holes in the wall/ceiling be careful not to damage concealed wires or pipes.)
5) Fix the luminaire to the wall/ceiling using suitable screws and fixings (not supplied).
6) Connect the mains supply wiring as follows.
7) For component protection in transit and user safety the luminaire battery fuse is supplied in the fitting.
8) When all connections have been made reassemble the fitting completely.
9) Restore the supply and check that the Green LED indicator illuminates to confirm the batteries are
charging. There are three possible reasons when the green LED indicator does not light up:
1) there is no power supply AC220-240V,
2) the batteries are not properly connected to the PCB,3) the batteries are not being charged.
10) Allow a short period for partly charging the batteries and then isolate the mains supply to the fitting in
order to check the correct operation of the fitting in emergency mode. After 36 hours on continuous charge
(and only at a safe time) a mains failure should be simulated to ensure that the fitting illuminates for its
rated emergency duration.
The luminaire will have a 1-hour backup after 14 hours charging and will be fully charged after 24 hours
(first charge 36 hours)
MAINTENANCE
Once the luminaire no longer meets the rated emergency operation the batteries must be replaced. AND
batteries must be replaced after a maximum of 4 years in service.
Repairs should only be carried out by a qualified person. Please recycle disposal of replaced components
where facilities exist. Special care should be taken if it's required to open the fitting as the fitting may still
be "live" even though the mains supply has been isolated. In these circumstances immediately disconnect
the battery supply.
Servicing and cleaning should only be carried out after the fitting has been made electrically safe. Cleaning
of luminaires should be carried out at regular intervals not only to ensure good optical performance but also
ensure that dirt does not accumulate to such an extent as to impair the electrical or thermal safety of the
fitting.
In case of any query/issue with the product, please reach out to us at: [email protected]
For More products range, inquiry please contact our distributor or nearest dealers.
V-TAC EUROPE LTD. Bulgaria, Plovdiv 4000, bul.L.Karavelow 9B
(N) Blue
(L) Brown
ENGLISH
Tabla de contenido
loading

Tabla de contenido