Fault - Angelo Po 091FR1ID Manual De Uso Y Instalación

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

8 - Check that the "slow
start-up" device is cor-
rectly positioned.
9 - Switch off the appliance,
turn off the gas supply tap ,
and disconnect the pres-
sure gauge (C) and retight-
en the screw (B).
10-Close the door (A) when
the operation is complete.
TROUBLESHOOTING
The appliance has been tested before being put
into service.
The information provided below is intended to as-
sist in the identification and correction of any anom-
alies and malfunctions which might occur during
use.

Fault

Smell of gas.
The flame is yellow.
The appliance does
not heat up.
The control panel does not
come on
FAULT
The user can solve some of these problems him-
self, but for others specific technical knowledge or
skill is required, and so they must only be carried
out by qualified staff with recognised experience
acquired in the specific sector of operation.
Causes
Occasional leak because flame
has gone out.
Burner dirty, heat exchange pipes
clogged, condensation drips.
Contactor not receiving power or
faulty.
Electronic circuit board not
receiving electrical power.
- 17 -
IDM-39603803100.tif
Remedies
Turn off the gas supply tap and
ventilate the room.
Information
Contact the after-sales
service..
Check the thermostat and activate
any start-up enabling device.
Check or replace the contactor
coil.
Check or swap the phase wire
connections.
270°
6
IT
GB
DE
FR
ES
English
Tabla de contenido
loading

Este manual también es adecuado para:

191fr2id

Tabla de contenido